2-2                                                      Q-Series

®

 Power – BAQ-UP™ (QRED) Redundancy Switch with Backup Amplifier – Installation & Operation Manual 

This wiring configuration is for a hub site with a primary

 

input and a backup input. In addition to the wiring 

method, the microprocessor is programmed at ATX to 

switch to the secondary input when the primary input falls 

below the threshhold level. When the primary level is 

restored within normal range, the QRED will switch back 

to the primary input immediately. This is an advantage in 

unmanned hub sites in that no level resetting is required 

after a primary path failure.

This wiring configuration is for a headend site with an amplifier that needs 

backup protection. This typically is used in the signal path where an amplifier 

failure is not acceptable. The QRED switch is programmed to switch to the 

secondary amplifier when the cumulative RF output of the primary amplifier falls 

below a programmed level, usually a 3 dB drop. This output is measured within 

a frequency range from 120-220 MHz. The microprocessor controlled switch 

can be programmed to switch within the end users specifications for timing and 

RF levels. Once a switch is made to the secondary amplifier, the signal path

 

continues through the secondary amplifier until a technician restores the 

 

primary amplifier signal levels and resets the switch manually.

SECONDARY (BACKUP) RECEIVER

PRIMARY (MAIN) RECEIVER

OUT

TO

PRIMARY

IN

FROM

PRIMARY

INPUT

DETECTOR

OUTPUT

SIGNAL OUT

DETECTOR

IN

FROM

SECONDARY

OUT

TO

SECONDARY

JUMPER

NC

NO

C

NC

NC

NC

NO

NO

NO

C

C

C

SIGNAL IN

PRIMARY (MAIN) AMP

OUT

TO

PRIMARY

IN

FROM

PRIMARY

INPUT

DETECTOR

OUTPUT

SIGNAL OUT

DETECTOR

IN

FROM

SECONDARY

OUT

TO

SECONDARY

SECONDARY (BACKUP) AMP

NC

NO

C

NC

NC

NC

NO

NO

NO

C

C

C

2.1  Functional Schematic

CHAPTER 2: DESCRIPTION OF OPERATION

Содержание Q-Series Power BAQ-UP

Страница 1: ...BAQ UP QRED Redundancy Switch with Backup Amplifier Q SERIES Power Installation Operation Manual ...

Страница 2: ... by one or more U S or foreign patents Other non ATX product and company names in this manual are the property of their respective companies Although every effort has been taken to ensure the accuracy of this document it may be necessary without notice to make amendments or correct omissions Specifications subject to change without notice ...

Страница 3: ...nstallation Operation Manual i TABLE OF CONTENTS Page 1 DESCRIPTION OF INTERFACES 1 1 2 DESCRIPTION OF OPERATION 2 1 2 1 Functional Schematic 2 2 3 SET UP PROCEDURE 3 1 4 SPECIFICATIONS 4 1 5 SERVICE SUPPORT 5 1 5 1 Contact ATX Networks 5 1 5 2 Warranty Information 5 1 ...

Страница 4: ...ii Q Series Power BAQ UP QRED Redundancy Switch with Backup Amplifier Installation Operation Manual This page left intentionally blank ...

Страница 5: ...over removed Input Test Point Output Test Point Gain Control Slope Control Input Pad used to optimize the input to the amplifier Description This is referred to as the secondary amplifier because your existing amplifier is referred to as the primary amplifier This internal amplifier has a low noise front end and is comparable in signal quality to any primary amplifier RF Switch Compartment Left si...

Страница 6: ...ED 5V power on Yellow LED warning On using reference levels stored in EEPROM Flashing 1 sec Needs to set reference levels Flashing 3 sec Switched to the secondary amplifier by the remote control switch Red LED alarm On Primary amp failure Flashing 1 sec Secondary amp failure Flashing 3 sec Input signal low primary amp and secondary amp failure RF Detectors Primary Amp RF Level Detector DC level pr...

Страница 7: ...ickly and set the alarms The system needs to be reset at this point to get back to normal operation after correcting the input levels If the system is running on the primary amp and the secondary amp level is down 3 dB or more the system considers the secondary amp failed and will set Alarm 2 and set the red LED flashing slowly The system should be reset at this point to get back to normal operati...

Страница 8: ...ed to switch to the secondary amplifier when the cumulative RF output of the primary amplifier falls below a programmed level usually a 3 dB drop This output is measured within a frequency range from 120 220 MHz The microprocessor controlled switch can be programmed to switch within the end users specifications for timing and RF levels Once a switch is made to the secondary amplifier the signal pa...

Страница 9: ...mpartment 10 Push the Set Ref Levels switch 11 Connect the and contact of the remote switch with a jumper to force the microcontroller switch to the secondary amplifier 12 Adjust the gain and slope control in the amplifier compartment to get desired signal level 13 Remove the jumper from the remote switch 14 Remove the signal strength meter from the Output of the RF switch compartment 15 Connect t...

Страница 10: ...3 2 Q Series Power BAQ UP QRED Redundancy Switch with Backup Amplifier Installation Operation Manual CHAPTER 3 SET UP PROCEDURE This page left intentionally blank ...

Страница 11: ...Q Series Power BAQ UP QRED Redundancy Switch with Backup Amplifier Installation Operation Manual 4 1 CHAPTER 4 SPECIFICATIONS SPECIFICATIONS 4 Specifications ...

Страница 12: ...4 2 Q Series Power BAQ UP QRED Redundancy Switch with Backup Amplifier Installation Operation Manual CHAPTER 4 SPECIFICATIONS This page left intentionally blank ...

Страница 13: ... Free 800 565 7488 USA Canada only Press 3 for Technical Support Then press 1 for Digital Video Products DVIS DigiVu UCrypt etc OR press 2 for All Other Products Email digitalvideosupport atxnetworks com for Digital Video Products Email jleskovar atxnetworks com for All Other Products CUSTOMER SERVICE ATX Networks 1 501 Clements Road West Ajax ON L1S 7H4 Canada Tel 905 428 6068 Toll Free 800 565 7...

Страница 14: ...nted in Canada Rev 07 15 ANW0849 1 501 Clements Road West Ajax ON L1S 7H4 Canada Tel 1 905 428 6068 Toll Free 1 800 565 7488 Fax 1 905 427 1964 Toll Free Fax 1 866 427 1964 www atxnetworks com support atxnetworks com ...

Отзывы: