2.2 Parameter Calibration setting & erasing
To achieve best level of protection of the pump, it is essential that parameter calibration must be done
immediately after successful pump installation or pump maintenance.
Setting the parameter calibration(Pump A)
- Press the key to switch to manual state, make sure the pump not running and LCD screen
displaying:
-
Press the key to run pump, confirm the pump and all pipe network in normal working state
(including voltage, running ampere et); LCD screen displaying:
- Press the button; The L932/B makes a "Di" sound and starts countdown, LCDscreen displaying:
- Pump A stops running and parameter calibration completed, LCD screen displaying:
Erasing former parameter calibration
When pump is reinstalled after maintenance or new pump is installed, user must erase the former
parameter calibration and a new calibration must be done.
Erasing the parameter calibration(Pump A)
- Press the key to switch to manual state, make sure the pump not running and LCD screen
displaying:
flash
flash
Installation & Operation Manual
L932/B
Pump A is ready for running
Intelligent Pump Controller
Note:Parameter calibration of pump B is
same as pump A,just by pressing
B START button instead of A START