37
ENGLISH, FRANCAIS
(et Canada)
•Installation
Effective 8/25/05
XT WATER HEATER
MPD 92690
REPLACEMENT VALVE KIT
10 GALLON
PATENT PENDING
1. Remove water lines (1), flexible hoses (2), mixing valve
(3) and inlet plumbing components (4).
2. Install new mixing valve (5) with teflon tape. Use three
wraps and pipe thread sealer to leading threads and
install to minimum 35 fl/lbs.
3. Install male/male 90 degree fitting with a minimum of
three wraps of teflon tape, stopping at approximately
1 o’clock on last turn.
4. Assemble tee to ball valve using a minimum of three
wraps of teflon tape.
5. Install valve/tee assembly to elbow using a minimum
of three wraps of teflon tape.
6. Finish turn on completed elbow/valve/tee assembly to
horizontal position.
7. Adjust tee and valve so valve handle operates and tee
is pointing branch thread upward.
8. Install flexible hose following instructions on hose tag.
9. Reconnect water lines. Apply Valve Position Sticker on
back near valve.
10. Pressurize system to maximum 50 psi and check all
connections for leaks with leak detecting solution.
2
1
3
4
5
10 GALLON TE
2004-2005
10 GALLON XT
NEW FOR 2005-2006
A Division of Dura Automotive Systems