DUCTING OPTIONS 

 
REQUIRED MINIMUM DISCHARGE  

Models 

Required Discharge Area 

AFM (16)(20) 

24 in

2

 

AFM (25)(30) 

36 in

2

 

AFM (35) 

36 in

2

 

Models using bottom discharge options 

48 in

2

 

Models using vertical discharge options 

48 in

2

 

 

 

Proper duct installation is critical to operation of furnace. When 
installing ducts, use materials rated for continuous use at 200°F. 

 

See minimum clearance to floorboards, walls & similar combustible 
building materials. 

 

Each 4-inch duct opening provides 12 in

2

 of discharge area. Provide 

an extra 12 in

2

 of non-closeable duct discharge area for each 

closeable register used. 

 

Use of 2” ducting does not count toward achieving minimum 
discharge requirements. Ducting into dead air space with no return 
air, such as holding tank areas, does not count toward achieving 
minimum discharge requirements. 

 

Adjust ducting installation to obtain air rise of 100°F-130°F. 

 

Horizontally installed furnaces – using side duct options – must 
have a minimum of one duct from both left and right side of casing. 

FLEXIBLE DUCTING SYSTEMS 

When designing flexible duct systems: 

 

Avoid sharp bends or crushed ducts. 

 

Stretch all ducts and run them directly to outlets, keeping quantity 
and angles of bends to a minimum. 

1. 

Remove knockout plates from desired outlets. 

2. 

Attach a duct adapter to each opening by inserting flange over 
casing, locking the tab into casing slot and turning adapter 90°. 

3. 

Attach and secure four-inch flexible ducts to adapters. 

4. 

Run ducts to desired location within RV, secure to registers. 

5. 

Additional ducting may be needed to maintain correct static 
pressure. 

 

 

 

Figure

 5

 

 

HARD DUCT FLOOR SYSTEMS 

 

When designing hard ducting systems: 

 

Undersized ducting will cause high temperature limiting. 

 

Oversized ducting will cause inadequate air flow from registers. 

 

When hard ducting is 1-1/2” in depth, an additional flex duct may be 
needed to maintain installation duct air flow requirements. 

 

DO NOT install floor registers within 2 feet of return air openings. 
See ducting option from casing top and bottom areas. These 
options can be with flex ducting or by hard ducting installations. 
Hard ducting must be sealed to insure proper operation of the 
appliance. 

 

HORIZONTAL OR VERTICAL BOTTOM DISCHARGE 

 

 

Figure 6 

 

Units can be installed as bottom or vertical bottom discharge 
systems. See figure 6 for cutout location and sizes. 

1. 

Remove bottom discharge knockout or side cover plate, these 
ducting options must be connected to a ducting system.  

2. 

Insure sealing of all joints when use of a gasket and plenum plate 
for hard ducting configurations.  

3. 

Other methods of sealing furnace to the floor are acceptable as long 
as clearances and seals meet requirements of clearances and 
temperature.  

4. 

Fasten plenum plate over floor cutout. If a gasket and plenum plate 
is not used seal furnace to hard duct system making sure seal is 
airtight. 

5. 

Position gasket on plenum over hole opening see Figure 6. 

6. 

Set furnace on gasket; make sure gasket remains in position. 

7. 

Additional ducting can be used to maintain correct air flow and 
temperature rise. 

FLEX ADAPTER PLATE  

 

Figure 7 

 

 

A flex adapter may be used to provide more flexibility for alignment 
of discharge opening on hard duct systems. This system can be 
used on all models installed horizontally providing ducting from rear 
of furnace without using side ducts. Use of a flexible mounting plate 
kit is available. See parts list. 

 
1. 

Cut a 4” x 12” opening over floor ducting. 

2. 

Remove three knockouts from rear of furnace. 

3. 

Install duct adapters in each opening see Figure 7. 

4. 

Place flex adapter plate with foam tape against hard ducting making 
sure openings line up. 

5. 

With plate held in place, fasten plate to ducting using screws or 
staples as need to keep it flat. 

6. 

Install three duct adapters into flex adapter plate. 

7. 

Attach flexible ducting from furnace to flex adapter plate and secure 
ducting in place on both ends. 

Содержание AFMD16

Страница 1: ... cabinet area as a storage compartment DO NOT vent furnace with venting system serving another appliance DO NOT vent furnace to an outside enclosed porch area DO NOT use for temporary heating of buildings or structures under construction Protect building materials from degrading from flue gas exhaust Protect furnace electrical components from water Compartment must be closed when operating unit Sh...

Страница 2: ...1 AFMD20111 AFMD20121 AFMD25111 AFMD25121 AFMD30111 AFMD30121 AFMD35111 AFMD35121 Type of Gas LP Propane LP Propane LP Propane LP Propane LP Propane BTU Input 16 000 20 000 25 000 30 000 34 000 BTU Output 12 160 15 200 19 000 22 800 25 840 Duct Static Pressure 20 WC 10 WC 10 WC 10 WC 10 WC Amperage AMPS 4 2 4 2 7 5 7 5 11 1 Watts 50 50 90 90 132 Power Supply Volt DC 12 12 12 12 12 Return Air 80 in...

Страница 3: ...ere wires pipes or other objects will interfere with installation or operation of furnace DO NOT install furnace on material that restricts return air such as directly on carpet or soft material like vinyl If you must install furnace on carpet or soft material install furnace on cleats or on a wood or metal panel extending the full width and depth of furnace plus minimum clearance to combustibles ...

Страница 4: ...ezel creating a sealing area 3 Pull furnace forward through cutout about a 1 inch slip bezel around casing and flush inner flange with casing 4 Secure bezel to furnace casing with 6 screws 5 Push furnace and bezel back tight against side wall and secure with 14 screws 6 When installing screws DO NOT deform bezel 7 Connect the gas line to the valve and push the gas line plug into casing opening 8 R...

Страница 5: ... needed to maintain installation duct air flow requirements DO NOT install floor registers within 2 feet of return air openings See ducting option from casing top and bottom areas These options can be with flex ducting or by hard ducting installations Hard ducting must be sealed to insure proper operation of the appliance HORIZONTAL OR VERTICAL BOTTOM DISCHARGE Figure 6 Units can be installed as b...

Страница 6: ...or servicing Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Disconnect electrical power before servicing CAUTION PROPERTY DAMAGE This connection is for low voltage battery or direct current only Do not connect to 120 or 240 volts AC POWER SUPPLY Atwood Mobile Products highly recommends the use of an electronic solid state converter with clean power...

Страница 7: ...come on 6 Allow 30 seconds for main burner to light after blower comes on This furnace is equipped with an ignition device which automatically lights the burner DO NOT try to light the burner by hand 7 If burner does not light repeat Steps 1 through 5 8 If after three 3 attempts with no ignition go to shut down and contact your dealer or a local recreational vehicle service agency Do not continue ...

Страница 8: ...8 WIRING AND LADDER DIAGRAM ...

Страница 9: ...9 PART DRAWINGS PART LISTS ...

Страница 10: ...10 ...

Страница 11: ...11 ...

Страница 12: ...nt de rangement NE PAS aérer la fournaise avec un système de ventilation pour entretenir un autre appareil NE PAS aérer la fournaise à un endroit extérieur fermé comme une véranda NE PAS utiliser pour le chauffage temporaire de bâtiments ou de structures en construction Protégez les matériaux de construction contre la détérioration par l échappement de gaz à combustion Protégez les composantes éle...

Страница 13: ...RTE 15 INSTALLATION DE LA PORTE PLANE 16 OPTIONS DE TUYAUTERIE 16 SYSTÈMES DE TUYAUTERIE FLEXIBLE 16 SYSTÈMES DE CONDUITS SOLIDES POUR LE PLANCHER 16 DÉCHARGE PAR LE BAS HORIZONTALE OU VERTICALE 17 PLAQUE D ADAPTATEUR FLEXIBLE 17 CONNEXION DE GAZ PROPANE 17 CONNEXIONS ÉLECTRIQUES 18 INSTALLATION DU THERMOSTAT 18 INSTRUCTIONS D UTILISATION 18 POUR METTRE HORS TENSION 19 SPÉCIFICATIONS MODÈLES Table...

Страница 14: ...roite Toujours installer la fournaise sur un mur avec paroi extérieure NE PAS installer la fournaise près d une chambre à bascule de murs coulissants de portes ou autres projections qui pourraient compromettre l échappement de la fournaise Placez la fournaise vers le milieu du guide pour l installation d une seule fournaise L installation doit être accessible si une réparation est nécessaire pour ...

Страница 15: ...sion d air de combustion Fixez au mur avec deux vis non fournies 15 L assemblage du conduit doit maintenir un chevauchement minimum de 1 1 4 po sur le tube d échappement et un minimum de 1 2 po du tube de combustion d air NE PAS excéder l épaisseur du mur 16 Fixez la fournaise au plancher avec deux vis à travers les pieds à l arrière du boitier Pour les appareils à la verticale maintenez la fourna...

Страница 16: ...omplètement scellé 11 Fixez le pied de montage au plancher pour une installation horizontale Pour les unités verticales retirez les vis des pieds du boitier et repositionnez le pied pour une surface de montage verticale pour maintenir la fournaise en position 12 Fixez la porte et le conduit avec les 6 vis fournies bonne pression statique OPTIONS DE TUYAUTERIE DÉCHARGE MINIMUM REQUISE Modèles Zone ...

Страница 17: ...hez les conduits flexibles de la fournaise à la plaque d adaptateur flexible et fixez le conduit en place sur les deux côtés 8 Des conduits additionnels peuvent être utilisés pour maintenir une bonne pression statique ou telle que désirée VÉRIFICATION DU FLUX D AIR Les appareils sont testés pour une augmentation de la température telle que spécifiée dans le plateau de classement Lorsque l installa...

Страница 18: ...de la fournaise 2 Connectez le câble rouge au côté positif du bloc d alimentation 3 Connectez le câble noir à la mise à la terre du bloc d alimentation 4 Connectez le fil bleu marqué positif du thermostat au côté du fil du thermostat en utilisant un fil toronné de 22 18 GA 5 Connectez l autre fil bleu à la tête du thermostat en utilisant un fil toronné d un minimum de 22 18 GA ALIMENTATION ÉLECTRI...

Страница 19: ...ve de fermeture automatique individuelle doivent être déconnectées du système de tuyau vers l approvisionnement en gaz durant le test de la pression du système aux tests de pression de plus de 1 2 po PSI Avant de connecter la fournaise le système de tuyaux doit être testé pour les fuites Le test doit maintenir la pression d air à au moins 6 po de mercure ou 3 PSI durant au moins 10 minutes Le syst...

Отзывы: