CRITICAL INSTALLATION WARNINGS

• Install in recreation vehicles only. RV’s are recreation vehicles

designed as temporary living quarters for recreation, camping, or
travel use having their own power or towed by another vehicle.

• All combustion air must be supplied from outside the RV, and all

products of combustion must be vented to outside the RV. 

• 

DO NOT

vent water heater with venting system serving another

appliance.

• 

DO NOT

vent water heater to an outside enclosed porch area.

• Protect building materials from flue gas exhaust.
• Install water heater on an exterior wall, with access door opening to

outdoors.

• 

DO NOT

modify water heater in any way.

• 

DO NOT

alter water heater for a positive grounding system.

• 

DO NOT

HI-POT water heater unless electronic ignition system

(circuit board) has been disconnected.

• 

DO NOT

use  battery charger to supply power to water heater even

when testing.

USA AND CANADA

FOLLOW ALL APPLICABLE STATE AND LOCAL CODES

-

IN THE ABSENCE OF LOCAL CODES OR REGULATIONS

REFER TO CURRENT STANDARDS OF

:

• Recreation Vehicles ANSI A119.2/NFPA 501C.
• National Fuel Gas Code ANSI Z223.1 and/or CAN/CGA B149 Installation

Codes

• Federal Mobile Home Construction & Safety Standard, Title 24 CFR, part

3280, or when this Standard is not applicable, the Standard for Manufactured
Home Installations (Manufactured Home Sites, Communities and Set-Ups),
ANSI A255.1 and/or CAN/CSA-Z240 MH Series, Mobile Homes.

• National Electrical Code ANSI/NFPA No. 70 and/or CSA C22.1
• Park Trailers A119.5
• CSA standard Z240 RV Series, Recreational Vehicle.

GENERAL INSTALLATION

This is a common installation for water heaters. There are other
approved methods such as Baggage Compartment (MPD 90093) and
Flush Mount (MPD 93948) installations. Consult with your Field
Auditor, Account Manager, or the Atwood Service Department if you
have additional questions.
1. Locate water heater on floor of coach before erecting side walls.

The water heater tank must be permanently supported at the same
level as the bottom of sidewall cutout (by the floor or a raised floor)

FIG

2. Provide adequate clearance at rear of unit for service of water

connections.

2. To install water heater on carpeting, you must install appliance on a

metal or wood panel that extends at least three inches beyond the
full width and depth of appliance.

3. If the appliance is installed where connection or tank leakage will

damage adjacent area, install a drain pan (which can be drained to
out side of coach) under water heater.

WIRING

All wiring must comply with applicable electrical codes.

COMBINATION GAS/ELECTRIC MODELS

are designed to operate with gas,

electricity, or a combination of both.

• Use electrical metallic tubing, flexible metal conduit, metal clad

cable, or nonmetallic-sheathed cable with grounding conductor. Wire
must have a capacity of 1400 watts or greater. The wiring method
must conform to applicable sections of article 551 of National
Electrical Code ANSI/NFPA 70.

1. Refer to 

Wiring Diagram

(

FIG

12). Make 120 VAC electrical

connections from junction box on back of unit.

a. Connect hot lead to (1) Black. 
b. Connect common lead to (2) White.
c. Connect ground wire from electrical service to (3) green ground

lead in junction box 3.

CAUTION

PRODUCT DAMAGE

• When using Romex

®

with a bare earth ground, take care to position

ground wire so it does not contact the heating element terminals.

• When a cord and plug connection to the power supply are used on

water heater, power cord must be UL listed as suitable for damp
locations, hard or extra hard usage. It must be a flexible cord such
as type S, SO, ST, STO, SJ, SJT, SJTO, HS or HSO cord as described
in National Electrical Code, ANSI/NFPA 70. The length of external
cord to water heater, measured to face of attachment plug, shall be
no less than 2 feet nor more than 6 feet. Supply cord must be a
minimum of 14 AWG and attachment plug must be rated at 15 amps.

CAUTION

ELECTRICAL DAMAGE

• 

Label all wires before disconnecting when servicing controls.

• 

Verify proper operation after servicing.

ELECTRONIC IGNITION 

NOTE

: It is recommended unit be connected directly to a 12V DC

battery or to filtered side of an AC/DC converter. Avoid connections to
unfiltered side of an AC/DC converter whenever possible. Use a
minimum of 18 gauge wire, UL and CSA listed.

1. Refer to 

Wiring Diagram

(

FIG

12). Install remote switch in a

convenient location. Position wall plate with letters up. Before
making connections turn switch 

OFF

2. Install wires see 

FIG

10 & 11.

PILOT RELIGHT - 

FIG

12

1. Install unit according to 

GENERAL INSTALLATION

instructions.

2. Refer to 

Wiring Diagram

. Use 18 gauge wire, UL/CSA listed.

3. Read 

PILOT

PILOT RELIGHT OPERATIONS

.

HEAT EXCHANGE MODELS - 

FIG

5

1. Push a 5/8˝ diameter coolant system hose (5-A) [with SAE 053 A

Type “E”clamp attached] onto heat exchanger tube (5-B) making a
tight connection.

2. Spread hose clamp and slide toward heat exchange unit past

annular groove (5-C) and release.

3. Continue to 

HOW TO OPERATE YOUR WATER HEATER

and/or 

Electronic

Ignition OPERATION

.

CONTINUE GENERAL INSTALLATION

4. Connect both 1/2˝ NPT water lines (

FIG

2) hot water outlet female

and cold water inlet female and 3/8˝ flared LP gas line to the water
heater (

FIG

9).

a. Allow flexibility in water and gas lines so you can pull unit

forward through wall one inch past skin.

b. Seal gas line entrance opening (

FIG

9) by sliding grommet (9-B)

onto 3/8˝ tubing (9-D) before flaring tubing (9-E). Pull gas line and
grommet through opening in housing (9-A). Connect flare fitting
(9-C) and press grommet into opening. If gas line tubing is
already flared, cut grommet on one side. Place split grommet
over gas line and press it into opening.

c. Always use pipe lubricant on threads when connecting hot and

cold water couplings. A suitable plastic fitting is recommended.

CAUTION

PRODUCT DAMAGE

• Do not lift, pull or push on main burner tube (

FIG

3-F).

5. Erect side walls and cut opening. See chart and 

FIG

1. 

Frame with 2x2 lumber (or equivalent).

CUTOUT 

(FIG 1 & 2)

CAPACITY

CUT OUT DIMENSION

DEPTH

Gallon

1-A

1-B

2-C

4 - 6

12-5/8˝

16-1/4˝

17-5/8˝

10

15-3/4˝

16-1/4˝

20-5/8˝

MINIMUM CLEARANCE FROM COMBUSTIBLE CONSTRUCTION

Sides:

Top:

Back:

Bottom:

6. Bend all flanges 90˚ along scored lines (

FIG

3-A).

7. To prevent water leaks caulk thoroughly around opening, including

bend slots. Butyl Tape (1-1/3˝x1/8˝) may be substituted for caulking
material.

8. Push unit against caulking, secure 4-corner brackets (

FIG

3-B) to

coach with No. 8 - 3/4˝ round head screws (not furnished) or equivalent.
Complete the installation by inserting the same type of #8 screws in the
holes provided around the flange of the water heater housing.

INTENTIONALLY LEFT BLANK

Содержание 10-E

Страница 1: ...ess of your revision number the current instructions are still generally applicable to your unit If you have questions contact your dealer an Atwood Service Center or the Atwood Service Department MOD...

Страница 2: ...ion box 3 CAUTION PRODUCT DAMAGE When using Romex with a bare earth ground take care to position ground wire so it does not contact the heating element terminals When a cord and plug connection to the...

Страница 3: ...occur or gas supply fail to shut off turn OFF manual gas control valve to appliance or turn gas OFF at the LP tank On ELECTRONIC IGNITION MODEL turn operating switch to OFF position and remove red wir...

Страница 4: ...and phone numbers of qualified Service Centers can be found at our website http www atwoodmobile com or call 574 262 2655 to have a Service Center List mailed WARNING FIRE OR EXPLOSION Shut off gas s...

Страница 5: ...of a recreation vehicle the Pressure Temperature Relief Valve will sometimes drip The Atwood water heater tank is designed with an internal air gap at the top of the tank to reduce the possibility of...

Страница 6: ...C A B A B B A 1 7 G 3 A F A B C D E F 5 A B E C D 4 6 ROBERTSHAW WHITE RODGERS From the Pump STRAIGHT SECTION VIEW 2 C D E C B I Cold Water Inlet Hot Water Outlet H 6...

Страница 7: ...7 4 6 5 O F F O N...

Страница 8: ...elief Valve Soupape de d charge de type 9 93870 93870 Solenoid Valve lectrovanne 11 91959 91959 Black on Off Switch Interrupteur Marche Arr t noir 91859 91859 White On Off Switch Interrupteur Marche A...

Страница 9: ...ite ci dessous se limite au remplacement ou la r paration du produit par un produit reconditionn la discr tion du fabricant La pr sente garantie est annul e si le produit est endommag du fait d un acc...

Отзывы: