15
Specifications
Dimensions
Dimensions
Valve body (ØxD)
73 mm x 26 mm
Target (WxDxL)
6 mm x 10 mm x 36 mm
O-rings (inside diameter x width)
Body sealing
54 mm x 2 mm
Poppet
0.72 mm x 1 mm
Target
2 mm x 1 mm or 2 mm x 0.8 mm
Connectors
Input gas connector
6 mm positionable Swagelok elbow, SS-6MO-2-2PR
High Voltage connector
Lemo
Cooling connections
6 mm Swagelok elbows, SS-6MO-9
Input / Output specifications
External input voltage range
0 to -350 V
Electrical capacitance
65nF
Electrical Power
50 W
Repetition rate
0-1 kHz
Electrical opening time
120
μ
s to 500
μ
s
Heat removal power
2 W (4-5 L/min of water)
Operating temperature
15°C ± 10°C
Gas backing pressure
0 to 5 bar
Performance
Physical opening time
down to 30
μ
s
Backing pressure
(bars)
Opening
voltage
(V)
Settings for the tests: 1 kHz repetition rate, 150
μ
s opening time.
The opening time is estimated from how much the valve trigger must be temporally detuned