background image

Explanation of a button setting function (1)

 

 Various functional set up in button operation.

●Set up the function

  ① Change Peak Hold (PEAK) and Tracking (TRUCK)
  ② Check Memory (MO) Data and Elimination of all memory data
  ③ Set up Comparator Function (HI)
  ④ Set up Comparator Function (LO)
  ⑤ Change Measuring Unit (UN)
  ⑥ Set up Over Load (OV)
  ⑦ Set up Power Auto Off(AP)
  ⑧ Set up Number of Digits on display / NP setting (NP)
  ⑨ Reverse Digital Display

  Power switch is turned ON while pressed the P-button. 

(Becomes MEASUREMENT MODE)     
(When there is no key 2-3minutes,a power supply is turned
 off automatically)
Keep to push F button about 6 seconds, indicate by FU 
(function).  (Becomes SETTING MODE)
Preparations the various setting were completed.

The programming procedure after FU display
① Change Peak Hold (PEAK) and Tracking (TRUCK)

  Change the Peak hold (PEAK) and change the tracking (TRUCK)

when pressed the D button. (Initial setting : TRACK)

  Push F button 

② Check Memory (MO) Data and Elimination of all memory data
”MO “ in the upper right side of the display.Can be
confirmed the memory date.   The memory data is advanced
when press the D button. (from M01 up to M50)

  Elimination of all memory data should press the RESET
  button. (Each data is not eliminable)
  The display indicate MO 0 when data is eliminated. (Initial

setting : 0)

                              ↓
  Push F button 

③ Set up Comparator Function (HI)

  Set up the upper limit of comparator function Figure rising
 by D-button and Digit rising by RESET-button.  When not
 using this function, setting to the 0. (Initial setting : 0)

                                     ↓
                                   

-8-                      ATTONIC

Содержание ARFS-02

Страница 1: ...ARFS Series OPERATION MANUAL ATTONIC CO LTD ATTONIC Digital Force Gauge ARFS series...

Страница 2: ...try electric industry and etc Features Our Digital Force Gauge is down sized and has original design for hand held use The display value can be displayed reversely Sampling Speed 1ms The digital range...

Страница 3: ...lue Regarding over load setting please see page No 9 Do not use other adapter Should other adapter be used there are possibility to breakdown or may lead to a fire Also do not charge or operate unit i...

Страница 4: ...1gf 0 001lbf 0 9 999N 0 999 9gf 0 2 200lbf 0 001N 0 1gf 0 001lbf 0 20 00N 0 2000gf 0 4 400lbf 0 01N 1gf 0 001lbf 0 50 00N 0 5000gf 0 11 00lbf 0 01N 1gf 0 01lbf 0 99 99N 0 9999gf 0 22 00lbf 0 01N 1gf 0...

Страница 5: ...pe Aluminum S 7 In case of 50N 500N type Steel Model and Description type A type B Cone type Flat type Hook type Extension Rod Fork Hook type Measuring Shaft SS 1 SS 2 SS 3 SS 4 SS 5 Material Aluminum...

Страница 6: ...2 3 4 ARF 20 MAX Capacity 200 0 N 20 00 Kg 44 00 lb CON D C P D F RESET MADE IN JAPAN External Input Output LCD Disply Reset Switch Function Switch Data Output Switch Power Switch Loadcell Connector...

Страница 7: ...NEVER CHANGE THIS DIAL It is used when the calibration at the manufacture LCD DISPLAY Using graphic LCD liquid crystal it is possible to show a feature character setting character numbers and charging...

Страница 8: ...ting data indication of peak hold and tracking Besides when the mode is function FU you can reset all of the memory data but cannot reset the data one by one and can alter the figure then the figure i...

Страница 9: ...NG MODE Preparations the various setting were completed The programming procedure after FU display Change Peak Hold PEAK and Tracking TRUCK Change the Peak hold PEAK and change the tracking TRUCK when...

Страница 10: ...case of setting 0 OVER LOAD will be indicated on display when the load is reached from 100 to 110 of full scale Push F button Set up Power Auto Off AP To push D button Set up the Power auto off 1 rel...

Страница 11: ...U PEAK 0000 N FU MO 0 PEAK 0000 N FU HI PEAK 0000 N FU LO PEAK 0000 N FU UN PEAK 0000 N FU OV PEAK 0000 N FU PEAK 0000 N FU PEAK 0000 N FU NP PEAK 0000 N FU AP Display reversed with D Switch It will b...

Страница 12: ...put COM Comparator HI Open Collector Output 50V 100mA Comparator GO Comparator LO Overload output Output COM 10 RS 232C Rx Please refer the following RS 232C Format 11 RS 232C Tx 12 Digimatic output D...

Страница 13: ...ATTONIC CO LTD 600 5 HIGASHI TAKADACHO TOYOHASHI AICHI 441 8115 JAPAN TEL 0532 41 5357 FAX 0532 41 4826 http www attonic co jp E mail info attonic co jp...

Отзывы: