RAID Level 1
ExpressNAV interface to determine the setup of
the array.
Hot Spare sleds
To set up RAID Level 1 with Hot Spare sleds
1
Connect to Diamond Storage Array services
(refer to
Accessing the Array
on page 17) and use
the CLI or enter ATTO ExpressNAV browser
interface
Advanced
CLI Configuration page.
2
Type
set QuickRAID 1 2
3
Type
SaveConfiguration Restart
4
The array is configured into one RAID Level 1
group with two Hot Spare sleds.
Exhibit 6.3-2
Mirrored stripe groups with LUN designations in a fully populated Diamond Storage Array. If sled 12 were
removed, the drives marked LUN 6 would be available but degraded (unprotected by mirroring). If both sleds 11 and 12 were
missing, LUN 6 would be unavailable.
Exhibit 6.3-3 Configuration of sleds in RAID Level 1: five LUNs with two Hot Spare sleds
Sled
1
2
3
4
5
6
7
8
9
10
11
12
Drive
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
LUN
1
1
1
1
2
2
2
2
3
3
3
3
4
4
4
4
5
5
5
5
6
6
6
6
Mirror
Partner 1
Partner 2
Partner 1
Partner 2
Partner 1
Partner 2
Partner 1
Partner 2
Partner 1
Partner 2
Partner 1
Partner 2
Содержание Diamond Array S
Страница 2: ......
Страница 3: ......
Страница 11: ......
Страница 25: ...14 SCSI connections...
Страница 33: ...22 Serial port access...
Страница 45: ...34 General CLI commands...
Страница 51: ...40 Serial port CLI commands...
Страница 55: ...44 Maintenance CLI commands...
Страница 63: ...52 JBOD...
Страница 67: ...56...
Страница 79: ...68 RAID interleave...
Страница 87: ...76 Copy drives...