background image

configuration is use for making selective and 
Sensitive precise measurement of frequency, 
by tuning to the signal and switching to zero 
scan.

In the closed-loop configuration, the tracking 
generator signal is fed into the device under 
test and the output of the device under test is 
connected to the analyzer input.

In this configuration, the spectrum analyzer/ 
tracking generator becomes a self-contained, 
complete 

(source, detector, and display) 

swept frequency measurement system. An 
internal leveling loop in the tracking 
generator ensures a leveled output over the 
entire frequency range. The specific swept 
measurements that can be made with this 
system are frequency response 

(amplitude vs. 

frequency),

 magnitude only reflection 

coefficient, and return loss. From return loss 
or reflection coefficient, the SWR can be 
calculated. Swept phase and group delay 
measurements cannot be made with this 
system; however, it does make some unique 
contributions not made by other swept 
systems, such as a sweeper/network analyzer, 
a sweeper/spectrum analyzer, or a sweeper/ 
detector oscilloscope.

Precision tracking means a every instant of 
time the generator fundamental frequency is 
in the center of the analyzer passband, and all 
generator harmonics, whether they are 
generated in the analyzer or are produced in 
the tracking generator itself, are outside the 
analyzer passband. Thus only the tracking 
generator fundamental frequency is displayed 
on the analyzer's CRT. Second and third order 
harmonics and intermodulation products are 
clearly out of the analyzer's CRT. Second and 
third order harmonics and intermodulation 
products are clearly out of the analyzer tuning 
and, therefore, they are not seen. Thus, while 
these distortion products may exist in the

measurement set-up, they are completely 
eliminated from the CRT display.

The 1dB gain compression level is a point of 
convenience, but it is nonetheless considered 
the upper limit of the dynamic range. The 
lower limit, on the other hand, is dictated by 
the analyzer sensitivity which, as we know, is 
bandwidth dependent. The narrowest usable 
bandwidth in turn is limited by the tracking 
generator residual FM and any tracking drift 
between the analyzer tuning and the tracking 
generator signal.    

1. Structural integrity

 

No obvious impairment and gilding damage, 
all outside components are well installation, 
reliable fasten and flexible operability. Warm 
up for one hour to inspect the performances.

2.

 

Inspection of Y-POS

 

Adjust Y-POS knob, occurs hand feeling by 
obvious locating point, Failures in adjusting 
the locating point will lead to all measured 
amplitudes are invalid.

3. Accuracy of frequency readout 

Not exceed

2% spectrum width +sweep span 

-3

+5*10 *center fre10kHz. 

4. Inspection of frequency range 

Output 0.15MHz~1050MHz frequency signal 
from a signal generator, screen should display 
the complete signals.

Inspect frequency range of tracking signal 
generator:

 connect output port with frequency 

counter, both output attenuation and 
bandwidth are zero, adjust CF knob, to check 
the signal generator could output 0.15MHz to 
1050MHz signal or not.

5. Inspection of reference level 

2dB at 500MHz

Output 500MHz frequency and -27dBm level 
signal, from signal generator to spectrum 
analyzer. Set spectrum analyzer CF at 
500MHz, scanwidth 20MHz/DIV, center 
frequency 400kHz, with zero input 
attenuation. And signal amplitude should up to 
top line.

Inspect the output level of tracking generator: 

connect input to output with a coaxial cable, 
with attenuation 30dB, maximum output, then 
amplitude should lower the top line than one

Mainly Performance 
and Calibration of 
AT6010/AT6011 Series 
Spectrum Analyzer

Gratitude.

6. Frequency Response

It means signal response of spectrum analyzer 
in measuring equal level and different 
frequency. Since the primary function of the 
spectrum analyzer is to compare signal levels 
at different frequencies, a lack of flatness can 
seriously limit its usefulness. 

7. Inspection of attenuators

(0~40dB)4*10dB

2dB step, 

2dB(40dB).

8. Residual response and 
interference immunity

Short circuit the input by connect a 50
terminal load to input port, then signal 
response should not appears in screen. 

Otherwise, it may seriously affect the ability 
of spectrum analyzer in analyzing small 
signals.

Replace the 50

 terminal load off input port, 

noise base line should not raise, especially the 
tracking source cannot affect the instrument. 
In a common room, no signal response 
appears in screen.

9. Inspection of sensibility

Sensibility should better than -90dB.
Output a -90dBm signal with a standard signal 
generator, set CF in the frequency, with IF 
20kHz, 1MHz/DIV scanwidth, video filter on. 
Spectrum analyzer is able to measure the 
signal.

10. Grass level

The typical value is 15dB when IF bandwidth 
is 400kHz, otherwise, the sensibility of he 
unit is too inferior to analyze smaller signal.

Содержание AT6010

Страница 1: ...hanks for using our products please read this manual thoroughly before operation ATTEN INSTRUMENTS RF Microwave Instruments Therefore Microwave Components Spectrum Analyzers Regulated DC Power Supply...

Страница 2: ...mine the fault point Electromagnetic Compatible EMC Testing measure the function of harmful electromagnetic wave to be transmitted by various electronic equipments In addition it can output AM FM demo...

Страница 3: ...ly connected to an AT6010 AT6011 series spectrum analyzer Signal feed via a 1 5m BNC cable When used in connection with a spectrum analyzer or measuring receiver the probes cable used to locate and qu...

Страница 4: ...m analyzers best partner Since the phone s receiving signals transmit by base station are instability normally between 70dBm to 90dBm and maybe weaker in some place or even no signal In order to make...

Страница 5: ...ny unintended operation The protection is likely to be impaired if for example the instrument shows visible damage fails to perform the intended measurements has been subjected to prolonged storage un...

Страница 6: ...F is the first intermediate frequency which passes through a waveband filter tuned to a center frequency of 1350MHz It then enters an amplifier and this is followed by two additional mixing stages osc...

Страница 7: ...center frequency is set to 500MHz If the baseline tends to move upwards when the attenuation is decreased it may indicate spectral lines outside the maximum displayable frequency range i e 1200MHz wi...

Страница 8: ...is more sensitive to low level distortion than a scope Sine waves may look in the time domain but in the frequency domain harmonic distortion can be seen The sensitivity and wide dynamic range of the...

Страница 9: ...signal means distinguishing it from its nearest neighbors The resolution of a spectrum analyzer is determined by its IF bandwidth The IF bandwidth is usually the 3dB bandwidth of the IF filter The rat...

Страница 10: ...ortion free range is called the spurious free dynamic range of the analyzer The display dynamic range is defined as the ratio of the largest signal to the smallest signal that can be displayed simulta...

Страница 11: ...ents are well installation reliable fasten and flexible operability Warm up for one hour to inspect the performances 2 Inspection of Y POS Adjust Y POS knob occurs hand feeling by obvious locating poi...

Страница 12: ...Front View AT6011 Front View AT6010...

Отзывы: