7
How to use pellet burner
Pellet burner needs air for combustion, so the boiler room has to have air channel. Air
channel for air inlet must jave at least same surface as chimney and it must be opened.
Pellet burner must not be started, until it is safely approved that smoke can freely go
through boiler and chimney into the enviroment air.
Pellets are feeded into PELH30A from external feeder connected to pellet container. For
better function and the most balanced feeding, the feeder should be leant under angle of
45°. Feeder should be able to feed at least cca 10kg of pellets per hour of continuous
operation / demand for pellet feeding.
Pellets have to be stored in well ventilated room without moisture or in specially adjusted
container.
NOTE:
PELH30A consists from components of high quality that must not be
replaced with spare parts of lower quality. If the components are replaced with other than
original spare parts, the validity of warranty expires.
Menu buttons and their functions
Funtions of burner are set per menu buttons under display. (see also options of settings
under Production settings, below).
How to change settings of pellet burner:
„M“ Menu/Enter: For activation of further records and ENTER/SAVE of changes.
„–„ For comeback in menu and reduction of adjustable values.
„+“ For advance in menu and increasing of adjustable values.
„E“ Exit/Escape: For exit form menu without saving of new values.