Technical description 

 

PELH30A is designed on basis of fuel feeding by principle of falling, when the pellet fall 
by  self-force  from  pellet  feeder  through  inlet  hose  and  inlet  tube  on  the  grate,  where  the 
combustion runs.  
PELH30A    has  electrical  ignition  that  automatically  ignites  pellets  fallen  on  the  grate. 
Ignition begins only after the thermostat gives instruction to burner. 
PELH30A  has  own  built-in  thernmostat  (for  the  case  that  there  is  no  boiler/external 
thermostat  installed,  resp.  combined  connection  with  room  thermostat).  Its  temperature 
sensor has to be inserted into suitable case in water jacket of the boiler.  The on- and off-
temperature
  is  adjustable  via  menu  buttons  of  the  burner.  Information  about  actual 
operation data is given on display. 
 
 
NOTE: Head for boiler temperature sensor must not be treated with contact liquid or 
paste.  
 
PELH30A  has  production  pre-set  range  of  output  14-30  kW  and  three  degrees  of  output:  
1 (14 kW), 2 (22 kW) and 3 (30 kW).  
 
Selected  output  degree  is  projected  on  display  during  operation.  It  is  possible  to  change 
output via menu buttons of burner and information on dipslay. It possible to change range 
of output in two levels - from 8 to 12kW and from 14 to 30kW and according to this there 
are three degrees of output from 8 to 12 kW or from 14 to 30kW in the extended menu.  
PELH30A has own self-cleaning grate mechanism. When thermostat reaches adjusted off-
temperature, cycle of burn-out begins and afterwards the grate moves out and it is cleaned 
by  scraping.  This  enables  longer  time  of  usage,  during  which  it  will  not  be  necessary  to 
remove burner from boiler. Amount of pellets that is possible to combust before the ash is 
removed  is  given  by  size  of  the  boiler´s  ashpan.  It  is  possible  to  prolong  this  interval  by 
automatic  ash  removal  from  boiler  into  ashpan  outside  of  the  boiler.  Burner  is  equipped 
with control system that regulates gear of the ash removing feeder. 
Convectional parts of boiler have to be cleaned in regular intervals to keep high efficiency 
of heating. 
 
 
PELH30A is intended for combustion of wood pellets with diameter of 6-10 mm. 
 
Burner  PELH30A  is  made  under  industrial  norms  and  prescriptions  and  it  was  tested  and 
approved  in  conformity  with  directives  about  low  voltage  appliances  as  well  as  with 
directives about electromagnetic  interference. 

Содержание PELH30A

Страница 1: ...Appendix Nr 1 PELLET BURNER PELH30A MANUAL FOR ATTENDANCE Manual for installation and start up EN 01 07 2010...

Страница 2: ...How to install pellet burner 14 Burner start 14 Burner stop 14 Emergency stop 15 Cleaning and maintenance 16 Troubleshooting 17 Possible causes of faults 18 Decomposed view 19 Spare parts and codes 2...

Страница 3: ...ions between boiler and chimney have to be airtight Overpressure in combustion chamber has to be min 5 Pascal 0 5mm of water column resp 0 05hPa The PELH30A appliance is intended for combustion of woo...

Страница 4: ...t via menu buttons of burner and information on dipslay It possible to change range of output in two levels from 8 to 12kW and from 14 to 30kW and according to this there are three degrees of output f...

Страница 5: ...lity If the box is damaged check burner for possible damage by transport Reclamation of damage by transport has to be recorded by spediteur Paper box shoul content these parts 1 pc Burner PELH30A 1 pc...

Страница 6: ...WARNING Electrical installation has to be done by certified electrotechnician Main cables can be replaced only by eletrotechnician approved by us Voltage and energy consumption Component Mains Volt M...

Страница 7: ...leaned grate moves out towards scraper and ash with unburned elements falls through fron wall of the burner s bottom into the ashpan After the grate shifted the burner waits for new signal from thermo...

Страница 8: ...us operation demand for pellet feeding Pellets have to be stored in well ventilated room without moisture or in specially adjusted container NOTE PELH30A consists from components of high quality that...

Страница 9: ...ing schedule MENU Explanation EFFECT ADJ Required output degree 1 2 or 3 PELLET TRIM Setting of feeded pellet ration LOG Record of faults for control purposes FINAL COMBUST Instruction to burner for b...

Страница 10: ...reasing amounts of pellets are feeded into burner until required pellet ration is achieved Step 4 Combustion Combustion phase runs until it is interrupted by thermostat Step 5 Burn out Thermostat inte...

Страница 11: ...terrupt operation from other reasons press the M button and the burn out regime begins For burner restart after ash removing press M Press the button This internal setting can be helpful by trobleshot...

Страница 12: ...1 2 3 8 10 12 14 22 30 8 12 14 30 kilowatt kilowatt Ignition setting 90 50 300 Test blow time 15 0 60 sec Transition phase 240 480 60 600 sec Transition pellet trim 15 10 50 Clean blow time 45 10 600...

Страница 13: ...12 Menu Settting See Extended Menu Log Saves error codes See Extended Languages Slovak English German Italian French Polish...

Страница 14: ...ing way by pressing of button go to Save settings and save your settings by M button Exit menu by E button Regulation of pellet dosing Before starting up of burner it is necessary to set pellet feedin...

Страница 15: ...een feeder s opening and inlet pipe of min 400mm In horizontal position there should be gap between inlet pipe and feeder s opening of min 1500mm i e not vertically aligned Fill container with pellets...

Страница 16: ...hermostat gives instruction to stop Burner is alternatively controled by thermal boiler sensor connected to TS1 inlet on the right upper side of the circuit board Make sure that connection is fixed in...

Страница 17: ...l the fuel in burner burns out Turn the burner off by burner switch and by the main switch plug out mains cord of the boiler from mains socket Open door with burner to cca 90 1 Put down burner cover a...

Страница 18: ...cell abnormal light 12 ERROR CIRCUIT BOARD OVERHEATED Temperature under cover is too high 13 ERROR TEMPERATURE SENSOR TOO LOW Faulty thermal sensor of built in operation thermostat 14 ERROR TEMPERATUR...

Страница 19: ...high temperature in boiler room Prevent from heat leakage 14 Faulty sensor of thermostat Replace sensor 15 Faulty sensor of thermostat Replace sensor 16 Faulty circuit board Replace circuit board 18 V...

Страница 20: ...19 Decomposed view...

Страница 21: ...Shield with covering bracket 14 Hearth covering 15 Sealing flange 16 End switch bracket 17 Pellet brake 18 Pin of end switch 19 Blind of suction 20 Tension spring 21 Platform of display 22 Burner cove...

Страница 22: ...21 El scheme of connection burner PELH30A...

Страница 23: ...removing 1 230 VAC Phase 2 230 VAC Directly earthed conductor 3 230 VAC Phase of thermostat 4 Ventilator Directly earthed conductor 5 Ventilator Phase 6 Feeder Directly earthed conductor 7 Feeder Phas...

Страница 24: ...23 Accessories Name Number Ashpan Pellet container 300l PEL9600 Pellet feeder 1 5 m long Pellet feeder 2 5 m long Pellet feeder 5 m long...

Страница 25: ...act person and electrotechnician Date of installation Installed by Address street ZIP Code City Telephone Cell phone Service record Date Servised Checked CO2 Flue gas temperature CO ppm Service perfor...

Страница 26: ...tom corner will be O 14 i e actual value of actuator output in kW To change actuator output press button until required value is displayed in the right bottom corner i g N 18 If you press M now this n...

Страница 27: ...mount feeded into burner after fire recognition Feeded amount will be gradually increased with every ration during set period Pre set from production is 15 from full ration for14kW Time setting of cle...

Страница 28: ...re is possibility to select these languages Slovak English German Italian French Polish Setting of output range Burner can operate in the output range of 8 12 kW or 14 30 kW acoording to the range sel...

Страница 29: ...t is possible to reload production or installation settings Accessible are three main options Loading of settings Saving of settings and Production settings Loading of settings means that you can rese...

Страница 30: ...ber Pellet feeder Trademark Length Serial number Settings of pellet burner Menu Production settings Options of settings Set to Output level 1 14kW 1 2 3 ON OFF temperature ON 72 C OFF 82 C Difference...

Страница 31: ...Settings of pellet burner Menu Production settings Options of settings Set to Output level 1 14kW 1 2 3 ON OFF temperature ON 72 C OFF 82 C Difference min 5 Pellet ration 95 50 200 Advanced menu Rando...

Страница 32: ...upozornenia ATTACK s r o producer reserves theright tochangetechnical parametersand dimensions of boilerswithout previous warning Der Hersteller ATTACK s r o beh lt sich das Recht der technischenVer d...

Отзывы: