2
ATTACK DPX - Wood gasifying boiler
- Assembly, control heat up and attendance training is perfomed by field engineer trained by
producer, who also fills in the protocol about boiler installation.
- At wood gasification, it comes to formation of tar and condensates (acids) in the fuel chamber.
Therefore the mixing device has to be installed with the boiler to keep minimum temperature of the
return water into boiler at 65°C.
Operation temperature of the water has to be in the range of 80-90°C.
- The boiler cannot permanently operate in the outout range lower than 50%.
- When using the circuiting pump, its operation has to be controled by detached thermostat to
ensure prescribed minimum temperature of return water.
- Boiler operation is ecological at nominal output.
- Therefore we recommend to install boiler with accumulation tanks and mixing device, which
ensures fuel saving of 20-30% and longer boiler and chimney life-time, together with more
comfortable attendance.
- If you cannot connect the boiler into accumulation, we recommend connect the boiler at least with
one equalisation basin with approximate volume of 25l per 1kW of the boiler´s output.
- Daily heating-up is necessary, when the boiler operates at lower output (summer operation and
D.H.W. heating).
- Use only dry fuel with humidity of 12-20% (output decreases with increasing humidity and fuel
consumption is increased).
- Correct boiler choice, i.e. its heating output is very important condition for economical operation
and correct boiler function. The boiler has to be chosen by nominal output adequate to temperature
losses of heated object.
- Boiler can be used only for purpose that it is intended to and only in the way described in
this manual.
- WARNING – After disconnection of operating boiler from electricity mains, the
burning continues further in attenuation regime. Do not open boiler door, until the
boiler temperature decreases under 40°C.
Guarantee for boiler is not valid if:
-it is not operated with prescribed fuel -not with wood of humidity lower than 20% or if it is used
with the fuel that is not prescribed by producer