background image

Integrated Access Controller  – Installation manual  

All rights reserved. © AAT HOLDING S.A.

 

 

To add 

card

 user (Method 3)

 

Add a 

series cards

 users – 

Block Enrollment

 

The card number must be consecutive.

 

(This operation is only for Zone 1)

 

1   0  User ID number  # Card number  #

 

Card quantity  #

 

Card quantity is between 1-2000.

 

(EM Card, the first 10 digits card number or last 8 digits 
card number on the card)

 

To delete a 

card

 user by card

 

Note: 

Users can be deleted continuously without 

exiting from programming mode

 

2   0   Read Card    #

 

The devices can automatically identify the card of Zone 
1 or Zone 2

 

To delete a 

card 

user by user ID

 

This option can be used when a user has lost 
their card

 

2   0   User ID number   #

 

 

 

To delete a card user by Card number

 

2   0   Card number  #

 

Users can be deleted continuously without exiting from 
programming mode

 

Card and PIN mode 

 (3  1  1  # for 

Zone 1

 or 3  2  1  # for 

Zone 2

)

 

To Add a 

card

 and 

PIN

 user

 

(The PIN is any 4~8 digits between 0000 & 
99999999 with the exception of 1234 which is 
reserved.)

 

Add the card as for a card user

 

Press 

 * 

 to 

exit from the programming mode

 

Then allocate the card a PIN as follows:

 

 *  Read card 1234 # PIN # PIN #

 

To change a 

PIN 

in card and PIN mode (Method 

1) Note that this is done outside programming 
mode so the user can undertake this themselves

 

 *  Read Card Old PIN #  New PIN #

 

New PIN #

 

 

 

To change a 

PIN 

in card and PIN mode (Method 

2)

 

Note that this is done outside programming 
mode so the user can undertake this themselves

 

 *  User ID number #  Old PIN #   New PIN #

 

New PIN #

 

 

 

To delete a 

Card and

 

PIN 

user just delete the 

card

 

2   0  Read Card    #  or

 

2   0  User ID number  #

 

Card ONLY mode  (

3  1  0  # for 

Zone 1

 or 3  2  0  # for 

Zone 2

)

 

To Add and Delete a 

card

 user

 

The operating is the same as adding and deleting a 
card user in 

Card or PIN Mode

 

 

 

To delete 

All users

 

To delete

 All users

 

Note that this is a 

dangerous

 option so use with 

care

 

2   0   0000   #

 

2   1   0000   #  Delete ALL users of Zone 1

 

2   2   0000   #  Delete ALL users of Zone 2

 

 

 

To set card users by Manager card 

(This operation is only for Zone 1)

 

To add Card User by Manager Add Card

 

Manager add card Read user card Manager add card

 

Cards can be added continuously.

 

To delete Card User by Manager Delete Card

 

Manager delete card Read user card  Manager delete 
card

 

Cards can be deleted continuously.

 

To unlock the door

 

For a 

PIN

 user

 

Enter the PIN  then press #

 

For a 

card

 User

 

Read card

 

For a 

card and PIN

 user

 

Read card

 

then enter

 

PIN #

 

Содержание Kade KZ-700-U/H

Страница 1: ...Installation Manual INTEGRATED ACCESS CONTROLLER KZ 700 U H VERSION 1 0 ...

Страница 2: ...s Controller Installation manual All rights reserved AAT HOLDING S A 2 1 Introduction 3 2 Features 4 3 Specifications 5 4 Controller installation 5 5 Controller wiring diagram 6 6 Detailed Programming Guide 8 CONTENTS ...

Страница 3: ... the KZ 700 U H is waterproof and con forms to IP68 The KZ 700 U H supports up to 2 100 users in a card 4 8 digits PIN card PIN option and additional 10 groups Duress PIN card The built in card reader sup ports both EM HID 125 KHz frequency cards tags The KZ 700 U H has many extra features including Duress PIN card block enrollment Wiegand 26 37 bits interface and backlight keypad etc These featur...

Страница 4: ...IN Read both 125KHz EM HID card PIN length 4 8 digits Pulse mode Toggle mode Wiegand 26 37 input output Can be worked as reader or controller Dual relay output for door opening door status detecting open door by button Card block enrollment With manager cards for adding or deleting card user easily Very low power consumption 25mA Backlight keypad Light and sound of keypad can be set Support door b...

Страница 5: ... 10 90 RH Environment Conforms to IP68 Adjustable Door Relay time 1 99 seconds Adjustable Alarm Time 0 3 minutes Wiegand Interface Wiegand 26 37 input output Wiring Connections Electric Lock Exit Button DOTL External Alarm Dimensions L128 x W82 x H28mm Net Weight 600 g Gross Weight 700 g Specifications Installation Remove the back cover from the keypad using supplied security screwdriver Drill 4 h...

Страница 6: ...C 2 Relay2 NC Black White COM2 Relay2 COM Pink NO2 Relay2 NO Red AC DC 12 24V DC 12 18V AC Regulated Power Input Red Black AC DC 12 24V DC 12 18V AC Regulated Power Input Brown D_IN Door Contact Yellow OPEN1 Request to Exit Button of Zone 1 Yellow Black OPEN2 Request to Exit Button of Zone 2 Grey Alarm Alarm Negative White D1 Wiegand Input Output D1 Green D0 Wiegand Input Output D0 Black GND Negat...

Страница 7: ...ges state which will not turn back until read card or input PIN again Reset to Factory Default To reset to factory default power off press hold it and power on release it until hear two beeps and the LED shines in orange then read any two EM or HID cards the LED will turn in red means reset to factory default setting successful ly Of the two cards read the first one is Manager Add Card the second ...

Страница 8: ...1 2 for Zone 1 or 3 2 2 for Zone 2 To add PIN users 1 1 User ID number PIN Zone 1 User ID 1 2000 1 2 User ID number PIN Zone 2 User ID 2001 2100 The PIN is any 4 8 digits between 0000 99999999 with the exception of 1234 which is reserved Users can be added continuously without exiting programming mode as follows 1 1 User ID number 1 PIN User ID number 2 PIN Zone 1 1 2 User ID number 1 PIN User ID ...

Страница 9: ...he card a PIN as follows Read card 1234 PIN PIN To change a PIN in card and PIN mode Method 1 Note that this is done outside programming mode so the user can undertake this themselves Read Card Old PIN New PIN New PIN To change a PIN in card and PIN mode Method 2 Note that this is done outside programming mode so the user can undertake this themselves User ID number Old PIN New PIN New PIN To dele...

Страница 10: ... inside buzzer and alarm output will both operate The Alarm Output time is adjustable between 0 3 minutes with the default being 1 minute Alarm output time To set the alarm output time 0 3 minutes 5 0 3 Factory default is 1 minute Door open detection setting To disable door open detection Factory default 6 0 To enable door open detection 6 1 Keypad Lockout Alarm Output options If there are 10 inva...

Страница 11: ...r To delete All Duress users Note that this is a dangerous option so use with care 2 3 0000 Note User ID number must be any 4digits between 2101 2110 Duress PIN card must be unique should be distinguished from common PIN card When the Duress PIN card is the same with common PIN card they will become invalid in Duress and worked as common user function KZ 700 U H supports Wiegand 26 37 both input a...

Страница 12: ......

Отзывы: