Detailed Programming Guide 

User Settings

 

To enter the programming mode

 

 *  Master code #

 

 888888 is the default factory master code

 

To exit from the programming mode

 

 *

 

Note that to undertake the following programming the master user must be logged in

 

To change the master code

 

 0  New code  #  New code #

 

The master code is any 6 digits

 

Setting the working mode:

 

Set valid 

card or PIN

 users

 

 

 

Set valid 

card and PIN

 users

 

 

 

 

 

Set valid 

card ONLY

 

 

 

3   1   2   # , Zone 1

 

3   2   2   # , Zone 2

 

Entry by 

card or PIN

(Factory default setting)

 

3   1   1   # , Zone 1

 

3   2   1   # , Zone 2

 

Entry by 

Card and PIN

 together

 

3   1   0   # , Zone 1

 

3   2   0   # , Zone 2

 

Entry by

 Card only

 

Note:

 When adding users, if the Card or PIN user has been enrolled already, you can not add it again to the 

same zone, or the device will give a bleep as error. But it is ok to enroll the same card or PIN for the zone 1 
and zone 2.

 

Card or PIN Mode - Factory default setting 

 ( 3   1   2   #  for 

Zone 1

 or 3   2   2   #  for 

Zone 2

)

 

To add 

PIN

 users

 

1   1  User ID number  #  PIN #  

Zone 1

: User ID: 1-2000

 

1   2  User ID number  #  PIN #

 

Zone 2

: User ID: 2001-2100

 

The PIN is any 4~8 digits between 0000~99999999 with 
the exception of 1234 which is reserved. Users can be 
added continuously without exiting programming mode 
as follows:

 

1   1  User ID number 1 # PIN# User ID number 2 #  
PIN #   

Zone 1

 

1   2  User ID number 1 # PIN# User ID number 2 #  
PIN #   

Zone 2

 

To delete 

PIN

 users

 

2   0   User ID number  #

 

Users can be deleted continuously without exiting pro-
gramming mode

 

To change the 

PIN

 of a PIN user

 

(This step must be done out of programming 
mode)

 

 *  User ID number #  Old PIN #  New PIN #

 

New PIN #

 

To add a 

card

 user (Method 1)

 

This is the fastest way to enter cards using ID 
number auto generation.

 

1   1  Read card  #  

Zone 1

 

1   2  Read card  #  

Zone 2

 

Cards can be added continuously without exiting pro-
gramming mode

 

To add a 

card

 user (Method 2)

 

This is the alternative way to enter cards using 
User ID Allocation. In this method a User ID is 
allocated to a card. Only one user ID can be allo-
cated to a single card.

 

1   1   User ID number  #  Read Card #  

Zone 1

 (User 

ID: 1-2000)

 

1   2  User ID number  #  Read Card #  

Zone 2

 (User 

ID: 2001-2100)

 

Содержание Kade KZ-700-U/H

Страница 1: ...Installation Manual INTEGRATED ACCESS CONTROLLER KZ 700 U H VERSION 1 0 ...

Страница 2: ...s Controller Installation manual All rights reserved AAT HOLDING S A 2 1 Introduction 3 2 Features 4 3 Specifications 5 4 Controller installation 5 5 Controller wiring diagram 6 6 Detailed Programming Guide 8 CONTENTS ...

Страница 3: ... the KZ 700 U H is waterproof and con forms to IP68 The KZ 700 U H supports up to 2 100 users in a card 4 8 digits PIN card PIN option and additional 10 groups Duress PIN card The built in card reader sup ports both EM HID 125 KHz frequency cards tags The KZ 700 U H has many extra features including Duress PIN card block enrollment Wiegand 26 37 bits interface and backlight keypad etc These featur...

Страница 4: ...IN Read both 125KHz EM HID card PIN length 4 8 digits Pulse mode Toggle mode Wiegand 26 37 input output Can be worked as reader or controller Dual relay output for door opening door status detecting open door by button Card block enrollment With manager cards for adding or deleting card user easily Very low power consumption 25mA Backlight keypad Light and sound of keypad can be set Support door b...

Страница 5: ... 10 90 RH Environment Conforms to IP68 Adjustable Door Relay time 1 99 seconds Adjustable Alarm Time 0 3 minutes Wiegand Interface Wiegand 26 37 input output Wiring Connections Electric Lock Exit Button DOTL External Alarm Dimensions L128 x W82 x H28mm Net Weight 600 g Gross Weight 700 g Specifications Installation Remove the back cover from the keypad using supplied security screwdriver Drill 4 h...

Страница 6: ...C 2 Relay2 NC Black White COM2 Relay2 COM Pink NO2 Relay2 NO Red AC DC 12 24V DC 12 18V AC Regulated Power Input Red Black AC DC 12 24V DC 12 18V AC Regulated Power Input Brown D_IN Door Contact Yellow OPEN1 Request to Exit Button of Zone 1 Yellow Black OPEN2 Request to Exit Button of Zone 2 Grey Alarm Alarm Negative White D1 Wiegand Input Output D1 Green D0 Wiegand Input Output D0 Black GND Negat...

Страница 7: ...ges state which will not turn back until read card or input PIN again Reset to Factory Default To reset to factory default power off press hold it and power on release it until hear two beeps and the LED shines in orange then read any two EM or HID cards the LED will turn in red means reset to factory default setting successful ly Of the two cards read the first one is Manager Add Card the second ...

Страница 8: ...1 2 for Zone 1 or 3 2 2 for Zone 2 To add PIN users 1 1 User ID number PIN Zone 1 User ID 1 2000 1 2 User ID number PIN Zone 2 User ID 2001 2100 The PIN is any 4 8 digits between 0000 99999999 with the exception of 1234 which is reserved Users can be added continuously without exiting programming mode as follows 1 1 User ID number 1 PIN User ID number 2 PIN Zone 1 1 2 User ID number 1 PIN User ID ...

Страница 9: ...he card a PIN as follows Read card 1234 PIN PIN To change a PIN in card and PIN mode Method 1 Note that this is done outside programming mode so the user can undertake this themselves Read Card Old PIN New PIN New PIN To change a PIN in card and PIN mode Method 2 Note that this is done outside programming mode so the user can undertake this themselves User ID number Old PIN New PIN New PIN To dele...

Страница 10: ... inside buzzer and alarm output will both operate The Alarm Output time is adjustable between 0 3 minutes with the default being 1 minute Alarm output time To set the alarm output time 0 3 minutes 5 0 3 Factory default is 1 minute Door open detection setting To disable door open detection Factory default 6 0 To enable door open detection 6 1 Keypad Lockout Alarm Output options If there are 10 inva...

Страница 11: ...r To delete All Duress users Note that this is a dangerous option so use with care 2 3 0000 Note User ID number must be any 4digits between 2101 2110 Duress PIN card must be unique should be distinguished from common PIN card When the Duress PIN card is the same with common PIN card they will become invalid in Duress and worked as common user function KZ 700 U H supports Wiegand 26 37 both input a...

Страница 12: ......