Problem

The unit does not detect or red LED
does not light.

The units detects only occasionally.

False Alarm

Red LED lights with no alarm output

LED blinks (once per second)
sending alarm output.

Possible Cause

Blocked by partitions or other objects.

Dip switch 1 is OFF.

Intruders (moving objects) do not cross
field of view.

Installed too close to electrical noise or
wired too close to the power or power
line.

Sudden temperature fluctuation.

Direct sunlight or intense headlight.

Fax or other electronic machines are
within coverage.

Controller is not armed.

Disconnection, poor connection, short or
poor insulation of the wire.

Alarm output is connected in parallel with
other outputs of the unit.

Self-diagnosis is active due to the
malfunction of the unit

Remedy

Remove the blocking objects.
Readjust coverage.

Turn the switch ON.

Readjust coverage so that intruders can
cross the field of view.

Relocate the unit.
Change the wiring route.

Remove heat source.
Readjust coverage.

Readjust coverage
Block the light with blinds.

Readjust coverage.

Arm the controller.

Check with a tester, and then fasten
terminal screws securely.

Wire in series with other outputs.
Use only one unit in one loop.

Replace the unit.

10

Trouble Shooting

11

Coverage

Top View

Side View

66ft.
(20m)

2.3ft. (0.7m)

Mounting height 20ft. (6m)

33ft.

(10m)

0

33ft.

(10m)

3.6ft.
(1.1m)

A-A

33ft.

(10m)

0

33ft.

(10m)

B-B

33ft.

(10m)

0

33ft.

(10m)

A-A

Mounting height 8ft. (2.5m)

3ft.
(0.9m)

33ft.

(10m)

0

33ft.

(10m)

B-B

Содержание IR36EXA

Страница 1: ...alk test in the protection area to check if alarm is activated Mirrors partitions and walls with high reflectance may detect temperature difference beyond the specified range Make sure no objects will...

Страница 2: ...0 80 AWG20 If more than one detector is added to the loop the maximum length per gauge decreases and is determined by dividing the length found in the chart by the number of detectors on the loop Use...

Страница 3: ...2 Firmly mount the base unit on ceiling with the mounting screws provided and route wiring as necessary to the rear of the base and through the wiring hole 3 Determine initial setup Please refer to 6...

Страница 4: ...detects malfunction of the unit Selection This function is active at all times regardless of switch settings Functions If the Alarm LED continues to blink after the one 1 minute warm up period a malfu...

Страница 5: ...eter height and 8 meter coverage 1 SIMULTANEOUS SETUP Rotate the adjusting plate to align V shaped protrusion with the desired mounting height In this case coverage of 20 meters in diameter is achieve...

Страница 6: ...wire Alarm output is connected in parallel with other outputs of the unit Self diagnosis is active due to the malfunction of the unit Remedy Remove the blocking objects Readjust coverage Turn the swi...

Страница 7: ...30VDC 0 1A resistor load 5 0 or less Form 1b NC contacts open when either body unit is detached from the base unit or base unit is removed from ceiling 30VDC 0 1A resistor load 1 0 or less 0 3 2 0m s...

Страница 8: ...ion on 9 Walk Test If furniture and or partition are moved in the coverage area Walk Test should be conducted At least once a year the whole system should be checked The user also needs to check the f...

Отзывы: