INSTALLATION 

 
 
GENERAL INSTALLATION GUIDELINES 
 
 
Environment 
 
The Series 3610 Time and Data Collection Terminal is a durable industrial-grade device, which will endure harsh 
environments.  The ATS terminal is designed to operate indoors and outdoors.  The NEMA 4X enclosure serves as 
a safeguard against splashing water, rain, windblown dust, and hose directed water.  The Series 3610 may operate 
with an internal heater element allowing functionality up to 110

°

 and down to –10

°

 Fahrenheit.  With a second 

heater option, the temperature range expands to –25

°

 Fahrenheit. 

 
The terminal should be mounted on a vibration free area.  Select a location, which has adequate lighting and 
accessibility to operate the terminal safely. 
 
 
Operating parameters 
 
The RS232 Series 3610 must be located no greater than fifty (50) wire-feet from the host computer.  EIA standards 
for RS232 protocol data transmission dictate this cable distance.  Exceeding this requirement greatly increases the 
chances for continual data re-transmission, which may never be acknowledged. 
 
 
 
 
 
 
 
 

 
 
 
 
 

(Side View)

8.5in

Seal-tight Connector

for Cabling

Nylon Plug

Содержание Accu-Time 3610 Series

Страница 1: ...M ME EN NT TA AL LL LY Y S SE EA AL LE ED D T TI IM ME E A AN ND D D DA AT TA A C CO OL LL LE EC CT TI IO ON N T TE ER RM MI IN NA AL L Accu Time Systems Inc 420 Somers Road Ellington CT 06029 Tel 860...

Страница 2: ...this manual may be reproduced or distributed in any form or by any means or stored in any database or retrieval system without Accu Time s prior written permission Accu Time Systems Inc makes no warr...

Страница 3: ...3 MANU3610 01 ACCU TIME SERIES 3610 TABLE OF CONTENTS Introduction 1 Features 2 Specifications 3 Installation 4 ACCU RATE Diagnostics 9 Maintenance 14 Troubleshooting Guide 15 MANU3610 01 01...

Страница 4: ...s can provide users with the flexibility to create a variety of options Reliability A Real Time Clock RTC provides 12 or 24 hour time formats with quartz precision An optional uninterruptible power su...

Страница 5: ...ard RS232 or RS485 compatible On board ACCU RATE terminal set up and diagnostics package Custom keypad legends with software defined function keys Large 20 key tactile 4x5 matrix keypad 4 line x 20 ch...

Страница 6: ...DI DO port and Auxiliary Serial Interface port Enclosure Molded fiberglass polyester sealed environmental housing for indoor outdoor use NEMA 4X approved Power 10 to 17VDC 12VDC 250 milliamps Nominal...

Страница 7: ...lity up to 110 and down to 10 Fahrenheit With a second heater option the temperature range expands to 25 Fahrenheit The terminal should be mounted on a vibration free area Select a location which has...

Страница 8: ...one before tightening the connector Power When terminal power is being supplied locally insure that a conventional 110VAC wall outlet 220VAC in Europe and other areas check local electrical code requi...

Страница 9: ...e use of ATS Series 1000 Network Controllers allows up to five hundred and twelve 512 terminals on a single host communication port 12 VDC POWER SUPPLY MULTI CLOCK RS485 INSTALLATION COMMADAPTER DB25...

Страница 10: ...the Series 3610 The supplied rubber tubing should be installed if the seal tight connectors do not properly secure either cable Place the jumper located at JP1 on the I O board to the NC position Figu...

Страница 11: ...D P GND VDC P GND JP1 JP2 DC POWER RS232 485 Communication Board J1 J2 Figure 2 If power is not supplied through the communication cable plug power into PJ1 Ensure that the jumper JP1 is placed in the...

Страница 12: ...he CLEAR key the user can step through the selections NOTE Test mode may be exited at any time by placing the Test Use switch back to the Use position and pressing the CLEAR key SELECTIONS ATS TEST MO...

Страница 13: ...The message KEY INPUT ACCEPTED is displayed Each time the ENTER key is pressed an internal test of the terminal s communication port is performed If an error is detected the message COMM PORT FAIL wi...

Страница 14: ...ed press the ENTER key to store the value and advance to the next parameter Address To change the terminal address 1 Press the CLEAR key to increment the address values from 01 to 32 2 When the desire...

Страница 15: ...S ENTER TO RETEST To perform the local communication loop back place the Test Use switch back to the Test position and press the ENTER key The following message should appear NETWORK TEST PASS ENTER T...

Страница 16: ...ARING MEMORY The green Valid LED will blink and the terminal will execute its power up sequence and return to the beginning of the Test Mode ATS AUX PORT TEST The ATS AUX PORT TEST will automatically...

Страница 17: ...n device The only required procedure is periodic cleaning of the badge reader To clean the badge reader swipe a pre moistened isopropyl alcohol cleaning card through the reader several times Low usage...

Страница 18: ...to the terminal blanking out Solution Check output of 12 volt DC power pack Solution Check for proper AC outlet voltage Possible cause Terminal does not go blank after unplugging the battery connector...

Страница 19: ...supervisor Possible cause Keypad connector is unplugged Solution Test keypad in the ACCU RATE test mode If all solutions have been explored and the problem still exists contact the Accu Time Product S...

Страница 20: ...ar installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try and correct...

Отзывы: