Trouble Shooting 
 

1. The picture is not clear. 

Clean the camera lens with a soft and dry cloth.  
 

2. There are black bars on the picture. 

Delete anything that could be affecting the camera. 
 

3. The picture is too bright or too dark and has very low contrast. 

Adjust the settings to change the contrast, brightness, etc until it meets your 
preference.  
 

4. The computer does not detect the USB-Device. 

Please try the following: 

1.  Check that the device is turned on. If a blue light is not shining out of the 

microscope lens, there is no power going through the meter.  

2.  Check that the computer meets the correct system requirements to use this 

meter. 

3.  If there is no window that says 

‘new removable device’

, check the USB 

device.  

4.  Try disconnecting the device, rebooting the system and trying again. 
5.  If you have connected the meter to a USB hub, please try connecting the 

microscope directly to the computer.  

6.  Check that your USB port provides enough energy to power the unit. If not try 

connecting it through a USB hub or if you have a ‘y’ cable try connecting the 
meter into two USB ports to provide more power. 

7.  Check that the correct driver is installed in your control panel. 
8.  Make sure that the USB device is connected to the same USB port used 

during installation of the hardware.  

9.  If this is still unsuccessful try uninstalling the hardware and installing again. 
10. Check that the USB port is still functioning correctly. 
11. Check that the USB port is activated in the BIOS (Basic Input/Output System) 

of your computer. 

12. Deactivate the ‘Legacy USB’ function in BIOS. 
13. If a USB device is not used for a while, windows will deactivate it. Reconnect 

the device and try again. 

14. If windows has a problem recognising the USB port when your motherboard 

uses an AMD 754 chipset. Please install the ‘Bus Master Drivers’. 

  

5. Each time you connect the device using the USB port, windows tries to re-
install it again. 

1. Check that you’re using the correct hardware driver. 
2. Make sure that you are using the same USB port that you used when installing the 
hardware.  
3. Uninstall the hardware driver and try again.  
 
 

Содержание DMS-USB2

Страница 1: ...USB Microscope Model No DMS USB2 Instructions for Use www atp instrumentation co uk ...

Страница 2: ...hnical support department for details about disposal and costs applicable Supplied in the box Before connecting the microscope to your computer please be sure to check that the contents of the box are all present USB microscope with a USB connection cable and protective lens cap Chrome Support Stand CD containing image processing software and drivers Instructions for use The ATP microscope is a mu...

Страница 3: ...ication Ratio 10X to 200X Shutter Speed 1 sec to 1 1000 sec Video Format AVI format White Balance Auto Exposure Auto Light Source 6 LED white lights adjustable light intensity PC Interface Mini USB 2 0 with 1 2m cable Operating System Windows 2000 XP Vista Power supply 5V DC from USB port Size 110mm x 33mm Ø Computer System Requirements Microsoft Windows 2000 XP and VISTA Pentium 300 or AMD Athlon...

Страница 4: ...ocess 4 Follow the instructions on the Digital Microscope Application Setup Wizard Once this has finished this icon will appear on your desktop If not the program will be found in Start All Programs under the name digi view 5 To complete the installation another window Vimicro USB 2 0 UVC PC Camera InstallShield Wizard will appear At this point the microscope needs to be connected to your computer...

Страница 5: ...en This is also the place where the resolution for the microscope is selected To change your settings Once in Digiview click on the settings button to access the settings screen Other buttons Help Settings Photo Library Video Library Record a Video Take a Photo Print the photo Delete the file E mail the file Ensure the correct imaging device is selected Select your resolution Standard image contro...

Страница 6: ...directly to the computer 6 Check that your USB port provides enough energy to power the unit If not try connecting it through a USB hub or if you have a y cable try connecting the meter into two USB ports to provide more power 7 Check that the correct driver is installed in your control panel 8 Make sure that the USB device is connected to the same USB port used during installation of the hardware...

Страница 7: ... to your computer the more time it needs to start and load up Wait until the boot process is finished before you connect the USB device You can not transfer files on the USB device 1 Check that there is enough memory free on your USB device Delete files that you no longer need or transfer them to your computer to free up the memory 2 Re format the USB device with FAT32 Please note that doing this ...

Страница 8: ...tation Ltd Tournament Way Ivanhoe Ind Est Ashby De La Zouch Leicestershire LE65 2UU Sales 01530 566800 sales atp instruments co uk Technical 01530 566804 technical atp instruments co uk www atp instrumentation co uk ...

Отзывы: