Factory Settings : 
E1 

The lowest value the end user can choose as the set point. 

E2 

The highest value the end user can choose as the set point. 

E3 

The differential. With a set point of 2°C and a differential of 4°C, the unit will cool until it  

      reaches 2°C. At this point, the compressor will then shut off and not come back on until the 
      unit reaches 6°C (2 + 4). The unit will cycle on and off between these two temperatures, 
      maintaining an average box temperature half way between. 

E4 

The compressor start delay is the shortest amount of time between the compressor cycling 

      off and coming back on. It also will delay the compressor from starting when the unit is     
      plugged in. 

E5 

E6 

will offset the temperatures read by the box and evaporator sensors. This setting is 

      rarely used. 

F1 

The maximum amount of time that a defrost 

can 

last. A defrost will last for the value set in  

      F1 

or 

until the evaporator sensor reads the value set in 

F3

F2 

The defrost interval controls how often the unit goes into defrost. A setting of six 

      corresponds to every six hours, or four times a day. In addition, the first defrost will start an  
      

F2 

number of hours after the unit is first plugged in. 

F3 

The defrost termination temperature value will bring the unit out of defrost before the full 

     amount of time set in 

F1 

has been reached if the evaporator sensor ever reaches the value 

     set in 

F3

F4 

The display during defrost. A setting of “00” will show the current box temperature as it rises 

     during a defrost, while a setting of “01” will lock in the last temperature value before the 
     defrost began. 

F5, F6, F7, F8 & F9 

are advanced settings and are advised not to be changed. 

C1 

The temperature display units. “00” for Celsius, “01” for Fahrenheit. 

Parameter 

Description 

Setting 

E1 

Low Set Limit, Celsius, (Fahrenheit) 

2°C  (36F°)

E2 

High Set Limit, Celsius, (Fahrenheit) 

20°C  (68F°)

E3 

Differential,  Celsius, (Fahrenheit) 

4°C  (7F°)

E4 

Compressor Star Delay, (Minutes) 

3 Min 

E5 

Case Temperature Offset, Celsius, (Fahrenheit) 

0

°

 

F1 

Maximum Defrost Duration, (Minutes) 

20 Min 

F2 

Defrost Interval, (Hours) 

6 Hours 

F3 

Defrost Termination, Celsius, (Fahrenheit) 

8°C  (46F°)

F4 

Display During Defrost  

C1 

Temperature Units, 0

 = 

 Celsius, (1

 = 

Fahrenheit) 

Содержание A1DP-RI30

Страница 1: ...Installation Operation Manual A1DP RI30 Please read these instructions completely before operating these units ...

Страница 2: ...General Case Information My Model is A1DP RI30 My Case Serial number is ...

Страница 3: ... shipping damage Apparent Damage A claim for obvious damage must be noted on the freight bill or express receipt and signed by the carriers agent otherwise the carrier may refuse the claim Concealed Damage If damage is not apparent until after the equipment is unpacked retain all packing materials and submit a written request to the carrier for inspection within 15 days of receipt of the equipment...

Страница 4: ...Case Dimensions ...

Страница 5: ......

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ...frost button for six seconds There will be an audible beep and the LED indicator for defrost will activate At default settings the defrost will last for 30 minutes At this point the defrost LED indicator will change from solid to indicate in defrost to a blinking indicator to indicate that the unit has just come out of defrost This blinking will continue for 15 minutes Changing Settings Press and ...

Страница 13: ...t goes into defrost A setting of six corresponds to every six hours or four times a day In addition the first defrost will start an F2 number of hours after the unit is first plugged in F3 The defrost termination temperature value will bring the unit out of defrost before the full amount of time set in F1 has been reached if the evaporator sensor ever reaches the value set in F3 F4 The display dur...

Страница 14: ...oo cold Is the compressor LED indicator on If the set point is lower than the current box temperature the compressor will stay on until it reaches the set point If the compressor LED indicator is not on Check for voltage out of terminal one on the back of the control There should not be voltage if the compressor LED indicator is not lit Check for voltage out of the compressor relay There should no...

Страница 15: ......

Страница 16: ......

Страница 17: ...rectly 2 Is the cabinet located in direct sunlight 3 Is the cabinet located in a strong air flow path 4 Is the distance between the upper surface of the displayed merchandise and the self directly above it at least 1 5 Is the unit away from the wall at least as 4 6 Is the air temperature around the cabinet above 75ºF Is there water in the door track or water leaking down the inside walls 1 Is the ...

Страница 18: ...s turned off before cleaning Un plug the electrical cord Avoid spraying cleaning solutions directly on surfaces fans or electrical connections Use a mild detergent warm water and a soft cloth When necessary water and baking soda will help remove case odors Avoid abrasive scouring powders or pads 1425 Osprey Drive Ancaster Business Park Ancaster Ontario Canada L9G 4V5 Tel 905 648 3741 Fax 905 648 9...

Отзывы: