background image

 

- 17 - 

normal use without adjustment but only switching gas. Adjust only by authorized 

and licensed technicians. When you change the gas source, you need exchange the 

corresponding pressure maintaining valve which installed on air intake.   

 

 

                   

  Fig.6                                                        Fig.7                   

 

9. Cleaning and Maintenance 

⚠︎

  Do not use any abrasive or flammable detergent to wipe; 

⚠︎

 

Do not hose down, immerse or pressure wash any part of the cooker, excluding 

the catch tray; 

⚠︎

 

Do not use abrasive cleaning matters to wash, even not use corrosive detergent! 

⚠︎

 

Grill cleaning/maintenance: 

(1)

 

when grill cools down, use a cloth with cleaning agent to wipe unit surface 

and residue; 

(2)

 

use a cloth with water to wipe unit surface; 

(3)

 

burning the main fire burner about 10-20 minutes for sterilization; 

(4)

 

no use for long time, spread cooking oil on grill after cleaning. 

Содержание ATTG Series

Страница 1: ...at www atosausa com For any service issues please kindly contact us at Email warranty atosausa com Or Toll Free 1 800 683 8660 Gas Countertop Griddles Operating Instructions Before you begin please read these instructions carefully to use this product correctly to make the product perform ideally and to avoid hazards ...

Страница 2: ... instruction manual in a safe place for convenient reference and operation This instruction manual is subject to any change without further notice and the manufacturer reserves the right of final interpretation The appliance is designed for commercial purposes not for household use A statement instructing the purchaser to post in a prominent location with instructions to be followed in the event t...

Страница 3: ... 2 Gas Countertop Griddles The Installation Operation and Maintenance Guide ...

Страница 4: ...on 4 3 Manufacture s Authority and Responsibility 5 4 Parameter Specifications 5 5 Transport and Storage 8 6 Installation and Debugging 9 7 Safety Notices and Precautions 12 8 Operating Instructions 14 9 Cleaning and Maintenance 17 10 Troubleshooting 20 ...

Страница 5: ...rding related matters of gas customers should execute the requirements of local gas supply sector If you smell a gas leak turn off the gas valves immediately and call the gas company The product should not be operated by those under 18 years of age or those with physical or mental disorders or disabilities that lack the necessary knowledge or experience unless with appropriate instructions and suf...

Страница 6: ...arties as the following reasons Not follow this instruction guidance and warning in using and testing Not in accordance with the requirements of technical parameters using this product Incorrectly or irrationally using the product by untrained personnel Not obey the local law using this product Be repaired or changed by unauthorized technicians Use the spare parts or accessories provided by non ma...

Страница 7: ... 6 ATTG 24 ATTG 36 ...

Страница 8: ...TTG 48 4 2 Information of Gas Supply and Burner The minimum supplied gas pressure regulator is factory set at 4 Natural Gas W C and 10 L P Gas W C The external thread of product s intake tube is 3 4 inches ...

Страница 9: ...25 000 75 000 42 L P Gas 10 25 000 75 000 53 ATTG 4 8 4 pieces Independen t control Natural Gas 4 25 000 100 000 42 L P Gas 10 25 000 100 000 53 5 Transport and Storage In the process of transportation handle carefully and keep upright to prevent damage of the product packing Wrapped equipment should not be in open air for a long time and shall be placed in a well ventilated and non corrosive gase...

Страница 10: ... system during any pressure testing of that system at test pressures in excess of 1 2psi 3 45kPa 6 1 Unpacking and Installation Please dispose of all packaging materials and residues after unpacking Check the equipment If it is damaged please keep wrappers and receipts which must be signed by the carrier representative Driver and contact the carriers to pursue a claim within 15 days after receivin...

Страница 11: ...level with other series of the equipment Please lift the equipment rather than drag if you need to move it Supplied gas pressure regulator is factory set at 4 Natural Gas W C and 10 L P Gas W C The equipment can only be placed on the incombustible counter top and keep a distance at least 6 inches 152mm to equipment s both sides and back and keep a distance at least 4 inches 102mm to the bottom Do ...

Страница 12: ...cordance with the instructions measuring gas supply pressure dynamic pressure in the work state Access to the equipment if measured data within the limits of Table 1 otherwise you will need to adjust gas pressure regulating valve or contact gas supplier to bargain Fig 1 Unplug pressure gauge after you accomplish pressure testing then install needle type pressure joint screw arbor Important make su...

Страница 13: ... the main gas valve extinguish all heat and flames and call 911 Safety information can be obtained from your local gas suppliers When using this equipment safety precautions should always be followed including the following The griddles burners grates and outside surfaces may become hot after using so you must be careful to touch During operation do not directly touch burners and plates Turn off t...

Страница 14: ...ization to this equipment otherwise may cause hazards and the manufacturer has the right not to provide warranty service Steel cutting producers used to manufacture with sharp edges The manufacturer has dealt with these sharp edges during production however we insist the operator take care when in contact with this piece of equipment Always keep hands hair and clothing away from heating source Wai...

Страница 15: ...urfaces of the unit Before leaving the factory the griddle plate is coated with protective coating as a rust inhibitor Heat the griddle to 200 300 to loosen and melt the coating then clean the surface with a non corrosive Rinse thoroughly and wipe dry with a soft clean cloth Clean all accessories Do not use corrosive or abrasives detergent Tip Season the griddle to avoid possible surface corrosion...

Страница 16: ...ompletely press the knob meanwhile light the fire by pilot with another hand Figure 4 Keep pressing the knob about 10 15 seconds then loosen the knob and observe stability of fire 4 If the pilot fire is not ignited please repeat the procedure above until the pilot fire is ignited 5 After successful ignition the main fire valve was opened turn left to the desired temperature figure 5 and the griddl...

Страница 17: ...ll continue to work Axial press the knob to rotate knob clockwise continually so that the direction of the knob on the off position at this time the fire extinguished the valve closed Fig 2 After turning off the equipment the main fire should be stop more than 5 minutes before next using 8 4 Exchange the main fire nozzle and the pilot orifice to switch gas source Remove control panel grill take of...

Страница 18: ... or flammable detergent to wipe Do not hose down immerse or pressure wash any part of the cooker excluding the catch tray Do not use abrasive cleaning matters to wash even not use corrosive detergent Grill cleaning maintenance 1 when grill cools down use a cloth with cleaning agent to wipe unit surface and residue 2 use a cloth with water to wipe unit surface 3 burning the main fire burner about 1...

Страница 19: ...ce as not in using If the equipment is not used for a long time clean the surface by wiping it with a soft cloth and place it in a well ventilated area Comprehensively check the equipment at least once every year by authorized and licensed technicians The product is made of 90 metals and cannot be discarded everywhere Deal with it in accordance with the local codes Instructions to clean appliance ...

Страница 20: ...ontrol panel Turn off valves when not in use Wipe panel and control valve knob with mild detergent daily Catch tray Pull out catch tray from front body until the equipment cools down Clean grease and other crumbs Reinstall after cleaning Warning if the catch tray is permitted to fill too high should be cleaned Per use ...

Страница 21: ...2 The main fire nozzle occlusion 2 Dredge nozzle 3 Gas control valves have problems 3 Change gas control valves 4 The pilot light and the main fire s distance is too far 4 Adjust the distance of them 5 Flame is too low 5 Adjust the height of the pilot light Close gas and heard a sound of fire 1 Insufficient gas pressure in pipe 1 Contact the local gas supply dept 2 Not match nozzle aperture with g...

Страница 22: ...lt occurs please stop using and contact technicians to check and repair Safety first turn off the power and gas supply before maintenance Notice 1 Pressure maintaining valve connects with air intake must be installed by authorized and licensed technicians to ensure interface tightness 2 Screw the hex nut Fig 8 before connect air intake ensure gas mark Fig 9 on the plastic core match with connected...

Страница 23: ... Fig 10 Our products have the advantages of good durability and low maintenance charge But to update some components and necessary maintenance can prolong life length of the products Contact the dealer for assistance ...

Отзывы: