- 12 -
bottom, in order to avoid influencing combustion and air circulation;
Leave enough distance in front of the equipment to take apart the
control panel. All major parts, in addition to the burner remove from the
front intake-tube;
It may be necessary to adjust the balance of air input by authorized and
licensed technicians;
Thread glue must be resistant to the action of liquefied petroleum
gases.
Warning! Use soap water or testing instrument to test whether
piping joint leaks or not before using, and forbid using an open flame to
test!
After installing completely, you should check gas supply pressure. Use a
pressure gauge which is equipped with liquid (such as U-type pressure
gauge, the minimum value is 0.1mbar) or a digital pressure gauge to test.
Steps are as following:
●
Remove top panel, and needle type pressure joint screw arbor (Fig.1),
then slip rubber tube of pressure gauge
over needle type pressure joint;
●
Start the equipment in accordance with
the instructions, measuring gas supply
pressure (dynamic pressure) in the work
state;
●
Access to the equipment if measured
data within the limits of Table 2,
otherwise, you will need to adjust gas
pressure regulating valve or contact gas
supplier to bargain;
●
Unplug pressure gauge after you accomplish pressure testing, then
install needle type pressure joint screw arbor.
Important: must screw
joint screw arbor, to prevent gas escape!
Ensure the pressure and no leaks of the appliance, Check the appliance
shall operate normally without flame lift or light back.