3.5.6
Multi-Point TCP Pair Connections
The difference between Multi-Point TCP Pair Connection and Multi-Point UDP Pair Connection
is that the TCP implementation would also exchange flow controls pins of RS-232. However,
the TCP Server is limited to a maximum of four connections. If there are than four serial devices
and does not use flow control pins of RS-232, it is possible to setup pair connection in UDP
mode,
Sec. 3.6.3
. After multi-connection is enabled in the WebUI, refer to the following table to
setup Pair Connection as in
Fig. 3. 31
.
Table 3. 2
IP Address
Link Mode
Local Listening Port
Destination IP
Destination Port
SE5002D Master COM1
10.0.50.100
TCP Server
5000
-
-
SE5002D Slave 1 COM1
10.0.50.200
TCP Client
-
10.0.50.100
5000
SE5002D Slave 1 COM2
10.0.50.200
TCP Client
-
10.0.50.100
5000
SE5002D Slave 2 COM1
10.0.50.201
TCP Client
-
10.0.50.100
5000
SE5002D Slave 2 COM2
10.0.50.201
TCP Client
-
10.0.50.100
5000
Fig. 3. 31
Содержание SE5002D-Fm
Страница 1: ...SE5002D Serial Device Server User s Manual v 1 2 October 2017...
Страница 15: ...Atop Serial Device Server SE5002D User Manual V 1 1 2 Getting Started 2 1 Hardware Panel Layout Fig 2 1 Fig 2 2...
Страница 16: ...Atop Serial Device Server SE5002D User Manual V 1 1 Fig 2 3...
Страница 17: ...Atop Serial Device Server SE5002D User Manual V 1 1 2 2 Pin Assignments 2 2 1 Serial Port Fig 2 4...
Страница 52: ...Atop Serial Device Server SE5002D User Manual V 1 1...