Packing List 

Inside the purchased package, you will find the following items

.

 

 

Table 3.1 Packing List 

Item 

Quantity 

Description 

MB52XX 

Industrial Serial Device Server 

Mounting Kit 

Wall-mounting screws (DIN-rail kit is optional) 

Terminal Block 

 

Power Supply:  

 

TB3 x 1: 3-pin 5.08mm Terminal Block   

Serial ports: Terminal block is included only on –TB or –SiS models 

 

TB5 x 1: 5-pin 5.08mm lockable Terminal Block (MB5201) 

 

TB5 x 2: 5-pin 5.08mm lockable Terminal Block (MB5202) 

Documentation 

Hardware Installation Guide 

(

Warranty card is included

)

 

 
Note

 

 

Notify your sales representative immediately if any of the above items is missing or damaged upon delivery

.

 

 

Atop

s  utility  software  Device  View©  and  Serial  Manager©  are  obsolete  and  replaced  by  Device 

Management Utility®

 

 

Table 3.2 Description of Optional Accessories 

Optional Accessories

 

Model Name

 

Part Number

 

Description

 

DK-25 

30200000000022G  Plastic DIN Rail Kit 

ADP

-

DB9

(

F

)-

TB5 

59906231G 

Female DB9 to Female 3

.

81mm, a TB5 Converter 

UN315-1212(US-Y) 

50500151120003G  Y-Type power adaptor, 100~240VAC input, 1.25A @ 12VDC 

output, US plug, LV6 

UNE315-1212(EU-Y)  50500151120013G  Y-Type power adaptor, 100~240VAC input, 1.25A @ 12VDC 

output, EU plug, LV6 

UV305-0510(US-DC)  50500051500003G  DC jack (3.5/1.35/7.5 mm) power adapter, 100~240VAC input, 

1.0A@ 5VDC output, US plug, LV6 

UVE305-0510(EU-
DC) 

50500051500013G  DC jack (3.5/1.35/7.5 mm) power adapter, 100~240VAC input, 

1.0A@ 5VDC output, EU plug, LV6 

UVE305-0510(UK-
DC) 

50500051500023G  DC jack (3.5/1.35/7.5 mm) power adapter, 100~240VAC input, 

1.0A@ 5VDC output, UK plug, LV6 

 

 

 

 

Содержание MB52 Series

Страница 1: ...MB52XX Modbus Gateway User Manual V 1 0 MB52XX Series Modbus Gateway User Manual V1 0 September 16th 2019 Atop Technologies Inc...

Страница 2: ...or ease of navigation For example click on any item listed in the Table of Contents to go to that page Published by Atop Technologies Inc 2F No 146 Sec 1 Tung Hsing Rd 30261 Chupei City Hsinchu County...

Страница 3: ...ecution All rights including rights created by patent grant or registration of a utility model or design are reserved Disclaimer We have checked the contents of this manual for agreement with the hard...

Страница 4: ...gement Utility 14 4 2 Configuring through Web Interface 16 4 3 Configuring Automatic IP Assignment with DHCP 17 4 4 Web Overview 17 4 5 Network Configuration 18 4 6 Basic Settings 19 4 6 1 COM Setting...

Страница 5: ...15 Modbus TCP Setting Page with TCP Master Operation Mode Selection 24 Figure 4 16 Slave ID Map Page with Slave ID Setting in Alias Mode 25 Figure 4 17 Slave ID Map Web Page with Slave ID Setting in i...

Страница 6: ...ult Settings 13 Table 3 5 Other Default Settings 13 Table 6 1 Hardware Specification 40 Table 6 2 MB5201 MB5202 Pin Assignment for DB9 to RS 232 RS 422 RS 485 Connector 41 Table 6 3 MB5201 MB5202 Pin...

Страница 7: ...1 3 Supported Platform This manual is designed for MB52XX Series Modbus Gateway and that series only 1 4 Manufacturers FCC Declaration of Conformity Statement NOTE This equipment has been tested and f...

Страница 8: ...isting devices or controllers running Modbus serial protocol Modbus ASCII or Modbus RTU to an Ethernet network The MB52XX Series are standard Modbus gateways that convert packets between Modbus TCP an...

Страница 9: ...terface between Modbus RTU ASCII host connected through Serial IP over Ethernet virtual communication port VCOM to Modbus RTU ASCII serial devices Figure 2 2 Use Cases of the MB52XX Series Modbus Gate...

Страница 10: ...ged upon delivery Atop s utility software Device View and Serial Manager are obsolete and replaced by Device Management Utility Table 3 2 Description of Optional Accessories Optional Accessories Model...

Страница 11: ...ppearance Front and Rear Panels The following figures show particular MB520X series device s front back side and top panels MB5201C Entry Level Semi Industrial Modbus Gateway MB5201 Industrial 1 Port...

Страница 12: ...roduct Atop will not be liable for any damages to property or personal injuries resulting from the installation or overall use of the device Do not attempt to manipulate the product in any way if unsu...

Страница 13: ...ameter Default Values Modbus Master TCP Settings TCP Master Mode TCP Master Port 502 Modbus Slave MB5201 MB5202 Mode RTU Slave Serial Configuration RS 232 9600 bps 8 data bits No parity bit 1 stop bit...

Страница 14: ...detect your Modbus Gateway and list it on Device Management Utility s window Alternatively if you did not see your Modbus Gateway on your network press Rescan icon a list of devices including your Mo...

Страница 15: ...is admin while the default password default After clicking on the Authorize button a notification window will pop up as shown in Figure 4 4 and some device may be restarted After the device is restart...

Страница 16: ...herefore the device can be accessed by using a web browser for configuring by entering the device s IP address default IP address is 10 0 50 100 in the URL field of your web browser Figure 4 5 illustr...

Страница 17: ...ically checkbox in the Network Setting dialog as shown in Figure 4 3 using Atop s Device Management Utility and then restart the device Once restarted the IP address will be configured automatically 4...

Страница 18: ...automatically Figure 4 8 Network Web Page At the lowest box in Figure 4 8 you will have the DNS Settings box which allows you to set the IP addresses of Domain Name Server 1 DNS 1 and Domain Name Serv...

Страница 19: ...ure the role of the serial device in your Modbus Gateway device and its serial communication parameters The term Operation Mode will be used to refer to the combination of role Master or Slave and the...

Страница 20: ...ps Software Selectable Parity None Odd Even Mark or Space Data Bits 7 or 8 Stop Bits 1 or 2 Flow Control None Software Xon Xoff Hardware RTS CTS Receiver Resistor On or Off Apply to all Serial Ports c...

Страница 21: ...of the devices connected through this VCOM port as shown in Figure 4 12 Its definition is the same to the one given in Section 4 6 2 Here the user can choose whether device conforms to a RTU or an AS...

Страница 22: ...Box for Applying the Settings to All VCOMSs After finishing configuring the VCOM Settings click on Save Configuration button to save all changes that have been made A Save Successfully message will sh...

Страница 23: ...ce will operate as a TCP Server that opens its TCP port to accept connections The TCP Master option will be described at the end of this section Remote IP Address This setting shows the IP address of...

Страница 24: ...f the list to select all items and click remove Alternatively the Modbus TCP connection can be configured to run in TCP Master Operation Mode This means that the device will be a Modbus Master node an...

Страница 25: ...e Slave Interface When a port is set to Modbus slave mode a slave interface will be created Select a radio button of a port number behind the Slave Interface which can be any one of the listed COM VCO...

Страница 26: ...ve ID Settings box there is a list of mapping entries as shown in Figure 4 17 in which each line will summarize an Entry No a Modbus Protocol a Source a Slave ID Setting Mode and the Slave ID Range Vi...

Страница 27: ...this box is not checked it means that SNMP is disabled Then the rest of the options will be disappeared as shown in Figure 4 18 If the SNMP option is enabled there can be three different views for SN...

Страница 28: ...3 Password is the password for SNMP account for SNMP v3 Encrypt is a drop down box which allows the user to choose the encryption scheme for SNMP v3 The available options are None DES or AES The defau...

Страница 29: ...B52XX Modbus Gateway User Manual Configuration and Setup Figure 4 20 SNMP Settings Web Page with SNMP Enabled and Version v1 v2c Figure 4 21 SNMP Settings Web Page with SNMP Enabled and Version Only v...

Страница 30: ...tings When enabled an E mail alert will be sent to the designated E mail addresses in the SMTP Simple Mail Transfer Protocol Settings To setup an email alert function the user needs to configure the s...

Страница 31: ...age that can trigger alert functions by checking the corresponding E mail boxes which are Cold Start is an event when power supply is interrupted Warm Start is an event when the device Restart functio...

Страница 32: ...he first three anomalies above This will send out alerts to an SNMP Trap Server Note that to configure SNMP Trap Server please see Section 4 7 After the Alert Events setting is complete click on Save...

Страница 33: ...the option to show all events by clicking the Show All Event button and the option to clear them all by clicking on Clear All Event button Figure 4 26 System Log Web Page 4 9 3 Data Log The log of Mo...

Страница 34: ...Web Page 4 9 5 Time Date and time can be set manually or through Network Time Protocol NTP to automatically synchronize date and time of the Modbus Gateway with a Time Server Figure 4 29 shows the Ti...

Страница 35: ...have been done A Save Successful message will show up with a hyperlink to restart the device as shown in Error Reference source not found Click the restart hyperlink to apply the changes Then a messag...

Страница 36: ...e Web Console by clicking on the corresponding radio button Additionally the user can protect how the user accesses the device with a Reset Button Protect option by checking on either No or Yes radio...

Страница 37: ...en click on the Import Configuration button to start the importing process After importing is complete the system will show a Save Successful message with a hyperlink to restart the device Click the r...

Страница 38: ...umber will show up After a successful device s restart the web browser will be redirected to the Overview page as shown in Figure 4 7 Figure 4 33 Factory Default Web Page 4 10 Restart For some unexpec...

Страница 39: ...MB52XX Modbus Gateway User Manual Configuration and Setup Figure 4 34 Restart Web Page...

Страница 40: ...RP Telnet RFC2217 Serial Serial Interface RS 232 RS 422 RS 485 Software Selectable Default RS 232 Serial Connector MB5201 1 Serial Port TB 5 or DB 9 MB5202 2 Serial Ports TB 5 or DB 9 Serial Port Comm...

Страница 41: ...ng Environmental Temperature Operations 40 C 70 C 40 F 158 F Storage 40 C 85 C 40 F 185 F Relative Humidity 5 95 55 C Non condensing 5 2 Serial port Pin Assignments 5 2 1 Pin Assignments for Serial In...

Страница 42: ...lour Status Message RUN Green Blinking System is booted up and AP Firmware is running normally On System is booted up and not running AP Firmware Off System is still booting up or powered off LAN Oran...

Страница 43: ...eimbursement Customers must always obtain an authorized RMA number from us before shipping the goods to be repaired When in normal use a sold product shall be replaced with a new one within 3 months u...

Страница 44: ...Main Rd Indiranagar Bangalore 560038 India Tel 91 80 4920 6363 E mail Abhishek S atop in ATOP INDONESIA BRANCH Jopson Li Branch Director Wisma Lampung Jl No 40 Tomang Raya Jakarta Barat 11430 Indones...

Отзывы: