You may desire a different field of coverage from the IR illuminator, if so, the beam is focus-

able. By turning the lens of the IR illuminator you will slightly change the beam width. 

NOTE: 

The IR will automatically turn off when the unit’s main power switch is turned to the OFF 

position.

LOW BATTERY INDICATOR

The low battery indicator is another feature that is programmed into your “Smart” scope. If 

the batteries start losing voltage LED “B” will start to pulse, it is time to change your batter-

ies.

USING THE CAMERA ADAPTER

 (OPTIONAL)

To use your MO-4 with a 35mm camera or camcorder you will need the following:
1) If you plan to use a camcorder then your camcorder must have a MACRO feature. Most 

modern camcorders today have a MACRO feature built-in.

2) If you plan to use a 35mm camera you will need a MACRO lens. If you don’t have one we 

advise that you contact your local camera store.

3) You may or may not need a STEP-UP or STEP-DOWN ring in order to adapt the camera 

adapter to your lens.

NOTE: 

The camera adapter comes with 37-mm and 52-mm threads. If you need other sizes your 

local camera store should be able to help.

• Remove the rubber eye-cup from the MO-4
• Screw the camera adapter onto the front of the lens on your Video camera’s lens or your 

35-mm camera’s lens.

• Loosen the three set screws on the camera adapter.
• Place the camera adapter over the MO-4’s eyepiece.
• Tighten the three set screws to fit snugly to the MO-4 eyepiece
• You may need to focus the 35-mm camera or video camera in combination with the MO-4 in 

order to get the sharpest image possible.

• We suggest that you find an open space to work in. Focus the MO-4 so that the scene is at its 

sharpest. For the best results you should disable the auto focus (if any) on either the 35mm 

camera or the video camera and manually focus the 35-mm camera or the video camera. 

Once the image is in sharp, then simply adjust the MO-4 front lens to change the focus.

• An important part to remember is that you are not taking a picture of an object that is far away 

from you, but you are actually taking a picture of a phosphorous screen of the MO-4 that is 

only 2-3 inches away.

USING THE 6X DOUBLER:

 (OPTIONAL)

• Unscrew 90 mm lens off the body of the MO-4 ( make sure that the unit is turned off).
• Screw the doubler into the body of the MO-4 where the 90 mm lens is removed.
• Screw the 90-mm lens into the doubler.

NOTE:

 When attaching the doubler do not be afraid to use a little force.

Screw

Camera adapter

Joint ring

Содержание MO4-1

Страница 1: ...AMERICAN TECHNOLOGIES NETWORK CORP u s e r s g u i d e MO 4 ...

Страница 2: ...ility for any errors or inaccuracies that may appear in this book 2001 ATN Corp All right reserved Power button Digital control for IR Digital control for Proximity Sensor Objective lens protective cover Built in infra red IR illuminator Computerized proximity sensor 5 Diopter 90mm F 1 2 lens for maximum clarity 3V lithium battery Doubler ON OFF indicator light IR indicator light Camera adapter ...

Страница 3: ...f and enter their sleep mode All the controls and buttons are digital Even if your batteries are low don t worry the smart series will let you know Our MO 4 scope has a 3 button digital control panel that allows the user to easily engage the main power Infra red illuminator and the proximity sensor Color coded LEDs let you know the mode of operation you are using 1 ON OFF indicator light when powe...

Страница 4: ...the rubber eye cup from the MO 4 Screw the camera adapter onto the front of the lens on your Video camera s lens or your 35 mm camera s lens Loosen the three set screws on the camera adapter Place the camera adapter over the MO 4 s eyepiece Tighten the three set screws to fit snugly to the MO 4 eyepiece You may need to focus the 35 mm camera or video camera in combination with the MO 4 in order to...

Страница 5: ...move the handle loosen the front lens and the eyepiece The handle then will be adjustable for left or right hand use Take your time learning about your smart scope It will take practice to properly use the device As you use this scope you will be able to improve your speed of focusing as well as sharpness of image Have fun and enjoy CLEANING THE EYEPIECE You may need to clean the eyepiece of the M...

Страница 6: ...ticles can be cleaned following instructions in Cleaning Eyepiece section Q Screen becomes darker than in previous use S Replace batteries If the problem persists contact your dealer or other authorized service representative for service instructions Q Image not clear S Adjust objective lens and or the eyepiece Turn on IR FEATURES SPECIFICATIONS Magnification 3x Optional 6x Intensifier Tube 1st or...

Страница 7: ...particular purpose shall apply to the product All such implied warranties are hereby and expressly disclaimed LIMITATION OF LIABILITY ATN will not be liable for any claims actions suits proceedings costs expenses damages or liabilities arising out of the use of this product Operation and use of the product are the sole respon sibility of the Customer ATN s sole undertaking is limited to providing ...

Страница 8: ...nden Ave Suite 1B South San Francisco CA 94080 phone 800 910 2862 650 875 0130 fax 650 875 0129 European Office phone 44 0 870 0111286 fax 44 0 845 3349142 The following countries can use our toll free number 00 800 9102 8620 Austria France Germany Holland Italy Spain Sweden Switzerland www atncorp com 2001 ATN Corporation ...

Отзывы: