manualshive.com logo in svg
background image

Cabin Series

Operating Manual

V1.0

IRay Technology Co., Ltd.

Содержание Cabin CBL19

Страница 1: ...Cabin Series Operating Manual V1 0 IRay Technology Co Ltd...

Страница 2: ...Battery power supply Battery type Capacity Output voltage Lithium ion battery pack IBP 2 3 1Ah 3 6V Operating duration 22 C h 7 5 External power supply 5V Type C Operational Specifications Ingress pro...

Страница 3: ...ow bad weather conditions are such as rain snow fog and haze etc Unaffected by the strong light and requiring no external light source it can even observe the targets hidden behind obstacles such as b...

Страница 4: ...port PIP picture in picture mode z Defective pixel calibration z Convenient user interface 4 Units and Controls 1 Lens cap 2 Laser indicator 3 LED light 4 Type C port 5 Power button 6 Up Zoom button 7...

Страница 5: ...P function on off Shortcut menu Main menu Navigation up Laser cursor calibration defective pixel calibration interface Move the cursor up left by one pixel Quickly move cursor up left Down Photo butto...

Страница 6: ...Type C end 18 of the data cable to the Type C port 4 of the product z Connect the other end of the data cable to the power adapter 19 that comes with the product or connect to another USB power socket...

Страница 7: ...nd align the orange line D on the battery pack 13 with the orange line C on the battery slot 21 and push the battery pack 13 into the battery slot 21 z When the battery pack is completely inserted int...

Страница 8: ...z Do not disassemble or modify the battery pack without professional instructions Do not knock or drop the battery pack z The recommended operating temperature for the device is 20 C 50 C Do not use t...

Страница 9: ...ns on the display After the adjustment is completed for the same user when using it again there is no need to adjust the diopter again z Rotate the lens focus knob 12 to focus on the object observed z...

Страница 10: ...r icon in the status bar that can be cancelled this calibration with a short press of the Power button 5 during countdown In this mode you can also press the Power button 5 for manual shutter calibrat...

Страница 11: ...stuck for 0 5s and a photo icon appears in the upper right corner of the screen z The photographed images are stored in the built in memory card Video Recording z On the home screen press and hold the...

Страница 12: ...to free up the space on the memory card The captured video or image does not display interface icon information Memory Access When the device is turned on and connected to a computer it will be recogn...

Страница 13: ...ion The timer will appear only after the microbolometer temperature has stabilized after 10 minutes of continuous operation of the device Immediately after turning on the device the shutter activates...

Страница 14: ...lecting this option press the Menu button 7 to adjust the image sharpness among 1 5 levels Image contrast After selecting this option press the Menu button 7 to adjust the image contrast among 1 5 lev...

Страница 15: ...abin when exiting from the main menu the cursor remains at the position before exiting When you restart the thermal imager and go to the main menu for the first time the cursor stays at the first menu...

Страница 16: ...ration mode Cabin provides three calibration modes automatic shutter calibration A manual shutter calibration M and background calibration B z Press and hold the Menu button 7 to go to the main menu i...

Страница 17: ...the digital compass is enabled its icon will be displayed in the middle of the status bar on the top Gravity Sensor Enabling Disabling the gravity sensor z Press and hold the Menu button 7 to go to th...

Страница 18: ...ndicates the X axis in the horizontal direction Y indicates the Y axis in the vertical direction Center means to return the cursor to the center of the screen Default means to return the cursor to the...

Страница 19: ...press the Up Zoom button 6 or Down Photo button 8 to select the Pixels Defect Correction option z Short press the Menu button 7 to enter the Pixels Defect Correction interface z A small cross cursor a...

Страница 20: ...us step you can delete it by short pressing the Power button 5 again Del is displayed in PIP z Each time you add or delete marking a blind pixel the quantity of defective pixel changes accordingly z W...

Страница 21: ...exit the calibration without saving within 15 seconds Standby Setting the standby state and duration z Press and hold the Menu button 7 to enter the main menu interface z Short press the Up button 6 o...

Страница 22: ...r the secondary menu of Settings z Short press the Up Zoom button 6 or Down Photo button 8 to select the Date option z Short press the Menu button 7 to activate re setting the date The date is in the...

Страница 23: ...to select the Time option The 24 hour view is used with hour and minute displayed z Short press the Menu button 7 to activate re setting the time z Short press the Up Zoom button 6 or Down Photo butto...

Страница 24: ...e option Short press the Menu button 7 to enter its secondary menu z Short press the Up Zoom button 6 or Down Photo button 8 to switch between English and Simplified Chinese z Short press the Menu but...

Страница 25: ...ault settings z Short press the Menu button 7 to enter the secondary menu of Settings z Short press the Up Zoom button 6 or Down Photo button 8 to select the Factory Reset option Short press the Menu...

Страница 26: ...Analog video Off Wi Fi Off Gravity sensor Off Language English Automatic status hiding Off Info Querying device information z Short press the Menu button 7 to enter the secondary menu of General Setti...

Страница 27: ...ed to 2 For example the image magnification on the home screen is 2 0 4 0 6 0 8 0 and the corresponding magnification value of the image displayed in the PIP small window should be 4 0 8 0 12 0 16 0 1...

Страница 28: ...button 8 Widen or lessen the measurement line to ensure that the measured object is within the line When you adjust the width of the measurement line the rangefinder data on the right changes accordin...

Страница 29: ...racking 20 Automatic Hiding This function is used to hide GUI with reticle displayed only so that there is no blocking on the image z In the main menu interface short press the Up Zoom button 6 and th...

Страница 30: ...password is 12345678 z After Wi Fi access you can control the device via the mobile App Setting Wi Fi name and password Cabin allows you to change the name and password of the Wi Fi in the App z After...

Страница 31: ...QR code z After installing the App open it z If your device has been connected to a mobile device enable mobile data on it After Internet access an update prompt will be displayed Click Now to downlo...

Страница 32: ...nt to wash the electric contact and slot of the battery z Check the glass surface of the eyepiece and lens If necessary clear off the dust and sand on the lenses preferably using a non contact method...

Страница 33: ...nnect to a smartphone or computer The Wi Fi password is incorrect Enter the correct Wi Fi password There are too many Wi Fi networks that are accessible to the device To enable stable network access y...

Страница 34: ...ies with the observed objects environment and background due to different heat conductivity coefficients As a result high temperature contrast occurs and the image quality is better At low temperature...

Отзывы: