Rainier Summit R1

PRODUCT SUBMITTAL

APPLICATION 

The AtmosAir Rainier Summit is a standalone self 
contained compact unit designed to increase ionization 
levels to restore indoor air to its natural state where no 
pollution or contaminants exist. The Rainier’s patented 
active ionization technology has been rigorously tested 

and scientifically proven to be extremely effective at 

reducing harmful particulates, irritating volatile organic 

compounds (VOC’s) and odors as well as significantly 

reducing mold, bacteria, viruses and germs in the air and 
on surfaces.
The R1 model is typically used for spaces up to 58.06 
square meters (625 square feet) in size. As odor 
concentrations are greater the effective range of the unit 
will be slightly decreased.
The R1 model uses 1 MC7 B ionization tube and is 

equipped with a MERV 11 filter. A carbon impregnated 
filter is also available in applications where pronounced 

odors exist The tube will need to be replaced every 2 years 

to ensure peak performance. The filter at the air intake of 

the unit will need to be periodically replaced as required.

SPECIFICATIONS

Figure 1

AtmosAir Solutions™

CAG-05-21-001

1-888-MYAIR11  |  AtmosAir.com

General Product Information

Air Flow Capacity

Variable; Up to 60 CFM

Treatment Area

58.06 SQ. M (625 SQ.FT) or

141.58 CU. M (5,000 CU.FT)

Housing Material

Powder Coated Steel

Weight

3.52 kg (7.75 lbs)

Maximum Operation 

Temperature

54.4° C (130° F)

Electrical

Voltage

120 to 240 VAC | 10 VDC

Frequency

50/60 Hz

Power Consumption

45 watts

Current Draw

0.63 Amps (0.630 mA)

Fuse

1.25 Amp

Field Electrical 

Connection

USA NEMA 15 Receptacle

EURO / UK / Japan / China

Ionization Tube

Material

Mono-Core Glass

Number

One (1)

Size

B (76.2mm) (3”)

Tube Life

17,600 Hours (Two Years)

Dimensions

13.5” (342.9mm) x 6.375” 

(161.9mm) x 7” (177.8 mm)

See Figure 1 for more details

Features

 

On/Off Switch on rear

 

Soft-Glow Blue LED Power Light on front

 

MERV 11 Filter or Carbon Impregnated Filter

 

Noise level on max fan setting at 1 meter = 45 dB-A

177.8mm

7"

161.9mm

6.375"

342.9mm

13.5"

Rainier Summit R1/R2

User Guide & 

General Maintenance

Содержание Rainier Summit R1

Страница 1: ...te where no pollution or contaminants exist The Rainier s patented active ionization technology has been rigorously tested and scientifically proven to be extremely effective at reducing harmful parti...

Страница 2: ...er Replacement Filter Replacement Filter Replacement Filter Replacement Filter Replacement Filter Replacement Filter Replacement Filter Replacement Tube Replacement enter date 3 months from above ente...

Страница 3: ...booklet before beginning the maintenance Follow each maintenance step exactly as shown and explained in this guide Observe all local state national and international electrical codes Pay close attenti...

Страница 4: ...osing Location 5 Unit Setup 5 02 GENERAL USE GUIDELINES 6 Unit Settings 6 Unit Settings Continued 7 Room Conditions 7 Care and Handling 7 Maintaining Your Unit 7 Maintaining Your Unit Continued 8 03 T...

Страница 5: ...et 37 m2 at 2 air changes per hour for spaces such as large bedrooms offices kitchens family rooms etc The best place to locate the unit is 4 to 7 1 2 to 2 1 meters off the floor in a central area wit...

Страница 6: ...It is always recommended to keep the Fan Speed at full power or fully clockwise as this will allow the system filter to trap the most dirt and the bi polar ions to be projected out into the room for o...

Страница 7: ...operating at top performance and trouble free Failure to follow the recommended maintenance intervals may result in premature wear of the unit and system failure which will not be covered by manufactu...

Страница 8: ...with the new filter Be sure to place the new filter in snugly and to note you are placing the filter in the correct orientation by noting the airflow direction arrow on the side of the filter Inside t...

Страница 9: ...ave been checked and a blown fuse is causing the malfunction Note If all the above steps have been performed and the unit still will not power on contact the reseller you purchased your unit from for...

Страница 10: ...CONTROL KNOBS OR INDICATIOR LIGHT THE ROTARY KNOBS AND SWITCHES WILL IMMEDIATELY BE DAMAGED AND NOT COVERED UNDER WARRANTY Either gently lay the unit on a rag piece of thick foam and let the knobs pro...

Страница 11: ...moved in order to open the unit They are located on the right and left side of the unit towards the bottom 3 Place the unit standing upright on one of its sides preferably on a towel or foam pad in or...

Страница 12: ...H TOO MUCH FORCE OR YOU MAY DAMAGE THE WIRES ON THE CONTROL KNOB SWITCHES 6 Once all four screws have been removed with the unit still on its side turn the back of the unit to face you 7 Using one han...

Страница 13: ...unit so that the ionization tube is facing you 10 To remove the tube use one hand to gently hold back the metal spring tang 11 With the other hand hold the plastic cap of the tube and spin the tube ou...

Страница 14: ...he tube into the tube holder Do not grab the glass or the screen Do not torque on the glass 15 Tighten carefully using the blue cap Tighten until the nut on the tube screw is contacting the metal tab...

Страница 15: ...com 17 Check that the spring tang is lying flat against the screen without edge contact as shown under step 18 18 Needle Nose Pliers can be used to adjust the spring tang to lay flat against the surf...

Страница 16: ...com 19 The unit is now ready to be reassembled Begin by gently sliding the two halves of the chassis together taking care not to pinch any wires between the metal parts 20 Tuck the black part of the...

Страница 17: ...holes use a Phillips no 2 screwdriver to start screwing in the two screws in one side but leave them loose Do not tighten them all the way until ALL screws have been inserted 22 Turn the unit over an...

Страница 18: ...S OF CLEAN AIR GROUP HERIN ARE EXPRESSLY GRANTED IN LIEU OF ALL WARRANTS WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURP...

Отзывы: