Instruction manual - GB
www.atmos.cz
GB-11
GB
4. Supplied boiler accessories
Steel brush with accessories
1pc
Poker - for boiler body cleaning
1pc
Cleaning fire hook - for cleaning burning chamber of the burner
1pc
Filling-in valve
1pc
Operating and maintenance instructions manual
1pc
Draught regulator - Honeywell FR 124
1pc
Automatic ash removal from the boiler drum
Each pellet type boiler produced after 1.3. 2007 can be fitted
with automatic ash removal from the boiler body into the ad-
ditional ash-pan, which will require emptying once in 3 to 45
days, depending on the quality of the pellets. For one minute,
this automatic device removes the ash from the chamber un der
the burner by means of screw conveyor in regular interval of
one hour (twelve hour) or according another setting in the ash
removal module. We can reset or repeat this cycle in the boiler
several times by switching the switch /29 (10)/ on and off. When
the additional ash-pan is completely full, the ash removal device
will stand off (a screw) and a sound signal will start. New start
up should be performed after cleaning the external ash-pan by
means of switching the switch /29 (10)/ on and off for 5 - 10
second (the B variation we do not make with a main switch).
The automatic ash-removal system does not need any specific operating procedures. Just
make sure that the additional ash-pan /30/ is emptied regularly. The con tainer is fitted to
the boiler by means of two clips with safety catches /32/. These clips must be fastened well
during the boiler operation so that no inadvertent release of the ash-removal device and
consequent transfer of ash into the boiler room may occur.
This device must be installed in
compliance with the supplied installation instructions. When installing the device, we follow
the installation manual delivered with the device. In case of wood burning put back the mov-
ing grate so that the wood do not fall into the ash-pan.