7
3.0 Setting up
Set up the device on a level, fi rm surface.
3.1
Operating elements
3.2 Connection
The main voltage specifi ed on the type plate must match
the power supply system.
Check mains cable for damages. Damaged cables must be
replaced immediately!
3.0 Setting up and starting up
3.3
Starting up
●
The ATMOS
®
A / C 161 Battery is delivered ready for
use.
●
Lift the unit out of the cardboard. Check whether the
voltage values on the data plate correspond with the
inbuilding voltage.
●
Prior to fi rst use, the battery must be fully charged!
●
Check whether the battery is fully charged, hereto
please press the battery test button (Figure 2,
)!
When the battery is fully charged, all display elements
will light up (Figure 2,
).
If this is not the case, please
recharge the battery (see chapter 3.4).
●
Set up the device on a level, fi rm surface.
●
Prior to fi rst operation, pay attention to the safety
information in chapter 2.0.
●
The unit must be allowed to stand for up to six hours at
room temperature prior to starting up for the fi rst time
following transport at temperatures below freezing. The
unit may
not
be operated if it has
not
acclimatised as
this might damage its diaphragms.
●
ATMOS
®
A / C 161 Battery DDS: At least one DDS
bacterial filter must always be available because the
device may not be operated without filter!
Fig 3.
Fig 2.
Fig 4.
Fig 5.
3.4 Charging the battery
The battery is charged by the 12 V low voltage connector (Fig. 4).
Chapter 9.3 contains a reference to the battery handling.
3.4.1 Charging with battery charging
power pack
Connect the low voltage connector (Fig 4,
) to the low voltage
socket at the device. Connect the mains plug of the battery
charging power pack (Fig 4,
) to the wall socket.
3.4.2 Charging with battery charger leads
(12V)
Connect the low voltage connector to the cigarette lighter in
the car.
With both methods, full suction capacity is available during
charging. Even with fully discharged respectively defective
batteries it is possible to operate the device via 12 V low
voltage connection. The full suction capacity is available. In
order to prevent the device from fully discharge it switches off
automatically after approx. 10 minutes.
Battery capacity approx. 35 min.
Vacuum gauge (only for ATMOS
®
C 161 Battery)
Vacuum control
On/off push button
Charge level indicator
Battery test button
Hose holder
Sliding cover for protecting the
control elements (only for ATMOS
®
C 161 Battery)
Hose rewind (accessory)
Fig 4a.
i
i
C 161 Battery
high flow/
high vacuum
20 % 40 % 60 % 80 % 100 %