background image

 

2. Important Safety Instructions 

 

For your satisfaction and safety, read this guide thoroughly before installing and using 

the HOTAP instant water heater tap.  

 

For best performance, this appliance must be installed in accordance with all electrical 

and plumbing codes applicable to your area, and as specified in this guide. 

 

Failure to comply with the safety, installation or operating instructions will void the 

product warranty.  

 

The product manufacturer and the product distributor will not be liable for any 

damages or injury caused by failure to comply with the installation and operating 

instructions specified in this manual or by improper use of the product.  

 

This appliance is suitable for both indoor and outdoor use. It is not intended for 

commercial use. 

 

This appliance must be connected to a household water supply. 

 

This appliance must be connected to a grounded power outlet. 

 

Do not turn on the water heater tap if it is not connected to the water supply. 

 

Do not attempt to install, clean, inspect, disassemble or service the tap without first 

shutting off all the power to the appliance by disconnecting the power cable from the 

power outlet. 

This appliance is not intended for use by small children or people with reduced 

physical, sensory or mental capabilities, unless they are properly supervised and 

instructed on the use of the water heater tap.  

Serious bodily injury or death can occur if you ignore this warning. 

 

If your water supply contains more than 200 ppm chlorine, it is recommended to use a 

water filtration system. 

 

If the water inside the tap freezes, it can cause damage that is not covered by 

warranty. Do not turn on the tap if you suspect water has frozen within the appliance. 

Wait until you are certain that the system has completely thawed before you turn it on.  

 

A mesh screen filter is installed on the water inlet, and should be removed and 

cleaned regularly.  

 

Use the handle to adjust the water flow, which in turn will increase (or decrease) the 

water temperature. 

 

The tap underwent factory testing for water leakage and energization. It is normal to 

find residual water at the inlet and outlet of the tap. Water should be flushed through 

the tap before use. 

 

Rated pressure of the tap is 0 kPa (0 bar). Make sure the water outlet is not blocked. 

 

If connecting a garden hose to the tap with a slanted spout, be sure the water outlet of 

the hose is not obstructed, to prevent continuous heating activation. 

 

If installing the tap with the electric cable below a metal sink or counter, make sure the 

hole through the counter is large enough for the electric cable to pass freely through it. 

The cable should also pass easily through the notches in the pedestal and rubber 

pads, as shown in the installation diagrams. Failure to install the electric cable 

properly could cause the wires to fray, which will void the appliance’s warranty. 

 

If you detect damage to the cable wires of the appliance, you must contact a qualified 

electrician to replace it with a cable from authorized dealers. Any damage to the wiring 

or integrity of the water heater tap should be assessed by a qualified electrician, and 

the tap should not be used until the unit or wiring has been repaired. 

Содержание HOTAP

Страница 1: ...Installation and Operation Guide HOTAP Instant Water Heater Tap www atmor net Cat No 197535 ...

Страница 2: ...cations 6 6 HOTAP Components 7 7 Electrical Diagram 8 8 Installation Guidelines 8 9 Installation 8 10 Operation Instructions 10 11 Maintenance 11 12 Troubleshooting 11 LIMITED WARRANTY 12 Read and follow the installation and operation instructions carefully to ensure the long life and reliable operation of this appliance ...

Страница 3: ...3 1 Packing List Item Quantity Instant water heater tap 1 Pedestal 2 Rubber pad 2 Mounting nut 1 Water inlet hose BSP 1 Aerator extractor tool 1 Installation and Operation Guide 1 ...

Страница 4: ...recommended to use a water filtration system If the water inside the tap freezes it can cause damage that is not covered by warranty Do not turn on the tap if you suspect water has frozen within the appliance Wait until you are certain that the system has completely thawed before you turn it on A mesh screen filter is installed on the water inlet and should be removed and cleaned regularly Use the...

Страница 5: ...es with international standard IP25 for protection against access of fingers and foreign objects to hazardous parts Liquid ingress protection waterproof Complies with international standard IP25 for protection against harmful ingress of water into the enclosure LED indicator Provides visual confirmation that heating element is active Overheating protection Shuts off power supply when water tempera...

Страница 6: ...Overheat protection 49 C Thermal cut out 85 C IP rating IP25 Minimum active pressure 80 kPa 0 8 bar Maximum active pressure 600 kPa 6 bar Water connection BSP Dimensions H 263 5 mm W 207 2 mm 64 5 mm The outlet temperature is determined by The temperature of the incoming water supply The kW rating of the unit The speed at which the water flows through the unit ...

Страница 7: ...e to the tap outlet by unscrewing the aerator and attaching the hose The garden hose outlet must always remain open to prevent heat buildup within the tap Threaded spout for optional attachment of garden hose To prevent heat buildup within the tap the water outlet must never be obstructed or closed off ...

Страница 8: ...ttings Before connecting to the power supply you must complete all mounting and plumbing connections and test the water supply Make sure water flows sufficiently and evenly Make sure there are no leaks Connect the tap s power cable to a grounded power outlet The outlet must be connected directly to a dedicated grounded circuit breaker on the main electrical panel 9 Installation The HOTAP instant w...

Страница 9: ... 1 as shown in the diagram 5 Make sure the mounting elements are aligned Then tighten the mounting nut and make sure the water heater tap is secure 6 Connect the water inlet hose to the HOTAP pipe 7 Turn on the water supply line Then turn the tap handle and test the water supply for adequate flow 8 After completing the installation and when operating the appliance for the first time allow cold wat...

Страница 10: ...facing up 12 o clock position cold water flows the strongest As the handle is pushed back the red indicator LED lights up and warm water begins to flow When the handle is fully backward 3 o clock position water temperature is the highest but flow rate is the lowest To maintain the hottest temperature you must keep the flow rate low If you will not be using the tap for an extended period it is reco...

Страница 11: ...package to remove the aerator from the spout as shown in the figure below Remove scale and dirt that may have accumulated in the aerator and then reinsert the aerator Removal of aerator in HOTAP 12 Troubleshooting Problems Possible causes Corrective actions No hot water comes out while the appliance is turn on No power Check power and cable connection Outlet water temperature is too high Water flo...

Страница 12: ...ater tap is guaranteed for a period of 12 months from the date of purchase The unit is guaranteed if it has been installed and maintained in accordance with the instructions contained in this installation and operation guide This guarantee specifically excludes Any HOTAP unit that has been not installed or maintained in accordance with the instructions in this guide Corrosion caused by incorrect i...

Отзывы: