6

TECHNICAL INFORMATION

item no. 

AT900-04

AT900-06

AT900-08

AT900-10

AT900-13

AT900-03

Phase

1

1

1

1

1

1

Voltage

240

240

240

240

240

110

Wattage (KW)

3.8

6.5

8.5

10.5

13

3

Amperage

16

27

36

44

55

27

Circuit breaker size

20

30

40

50

55

30

Required wire size (min)

12 AWG

10 AWG

6 AWG

6 AWG

4 AWG

10 AWG

Minimum water flow to 

activate unit

0.5 GPM

0.5 GPM

0.5 GPM

0.5 GPM

0.5 GPM

0.5 GPM

Weight (lb)

3.4 lb

3.4 lb

3.4 lb

3.4 lb

3.4 lb

3.4 lb

Dimensions (in) (HxWxD) 7.3x11.8x3.55 7.3x11.8x3.55 7.3x11.8x3.55 7.3x11.8x3.55 7.3x11.8x3.55 7.3x11.8x3.55
Nominal water volume

0.11gal / 0.42 l 0.11gal / 0.42 l 0.11gal / 0.42 l 0.11gal / 0.42 l 0.11gal / 0.42 l 0.11gal / 0.42 l

Working pressure

8 bar (115psi) 8 bar (115psi) 8 bar (115psi) 8 bar (115psi) 8 bar (115psi) 8 bar (115psi)

Texted to pressure

16 bar (230psi) 16 bar (230psi) 16 bar (230psi) 16 bar (230psi) 16 bar (230psi) 16 bar (230psi)

Water connections

1/2" NPT

1/2" NPT

1/2" NPT

1/2" NPT

1/2" NPT

1/2" NPT

MODEL GUIDE

Model 

240V

208V

110V

120V

AT900-04

3.8 kW

2.8 kW

-

-

AT900-06

6.5 kW

4.9 kW

-

-

AT900-08

8.5 kW

6.4 kW

-

-

AT900-10

10.5 kW

7.9 kW

-

-

AT900-13

13.0 kW

9.8 kW

-

-

AT900-03

-

-

3.0 kW

3.5 kW

Содержание 900 series

Страница 1: ... upon demand while conserving electricity water and energy The In Line is the most advanced heater in the Instant family and as such can be installed anywhere and serve any purpose When the flow switch turns on the electrical current the heating element heats only the amount of water economically needed for use 900 Series Hot Water on Demand InLine ...

Страница 2: ...all national state and local plumbing and electrical codes Service of the unit must be performed by qualified service technicians Before proceeding with any installation adjustment alteration or service of this unit all circuit breakers and disconnect switches servicing the unit must be turned off Failure to do so could result in serious personal injury or death Danger Never remove the unit cover ...

Страница 3: ...coming water line cold only on the bottom left side and the outgoing water line to the bottom right side Please check that there is no water leakage from the unit 5 Connect and lock the electric lines to each corresponding connector It is required that this device be properly grounded 6 Turn on the unit and check that it is operating as required 7 Reconnect the cover to the base with 4 screws 8 It...

Страница 4: ...flow restrictor will limit the flow and increase the output water temperature You may choose the low medium or high settings on the heater as required to achieve the water temperature desired Setting 0 OFF No heating lamp will not light Setting 1 Low heating lamp 1 will light Setting 2 Medium heating lamp 2 will light Setting 3 Maximum heating both lamps will light For 220V 240V 3 5kW unit only po...

Страница 5: ...odel V ac kW AMPS Min Field Wire AWG Min Ground Wire AWG Model V ac kW AMPS Min Field Wire AWG Min Ground Wire AWG 3 0N 110 120 3 5 30 10 10 6 0N 220 240 6 0 25 10 10 3 8N 110 120 4 4 37 6 10 6 5N 220 240 6 5 27 10 10 8 5N 220 240 8 5 35 6 10 3 5N 220 240 3 5 15 14 14 9 5N 220 240 9 5 40 6 10 3 8N 220 240 3 8 16 12 12 10 5N 220 240 10 5 44 6 10 5 5N 220 240 5 5 23 10 10 11 0N 220 240 13 0 55 4 8 N...

Страница 6: ...in HxWxD 7 3x11 8x3 55 7 3x11 8x3 55 7 3x11 8x3 55 7 3x11 8x3 55 7 3x11 8x3 55 7 3x11 8x3 55 Nominal water volume 0 11gal 0 42 l 0 11gal 0 42 l 0 11gal 0 42 l 0 11gal 0 42 l 0 11gal 0 42 l 0 11gal 0 42 l Working pressure 8 bar 115psi 8 bar 115psi 8 bar 115psi 8 bar 115psi 8 bar 115psi 8 bar 115psi Texted to pressure 16 bar 230psi 16 bar 230psi 16 bar 230psi 16 bar 230psi 16 bar 230psi 16 bar 230ps...

Страница 7: ... affect the temperature increase The heater should be mounted No more that 12 18 inches from the point of use Flow Rate Controlling flow rate is essential to insure proper temperature increase Check your flow rate to insure proper operation of the heater The activation flow rate Needed to turn on the heating Element has not been reached Low flow rate In the case of the low flow rate heater it is m...

Страница 8: ...return the water heater for repair the owner must first secure a written authorization from Atmor The owner shall be required to show proof of purchase date and to pay all transportation costs to return the defective part s or water heater for repair or replacement Warranty is void if i water heater has been installed or used improperly ii design has been altered in any way iii water heater has be...

Отзывы: