background image

5

Testing the ATSTK94

2449A–FPSLI–01/02

Table 1.

Default for Jumpers and Switches

Jumper/Switch

Default Position

JP 1-16

The default position for all the switches and LEDs is with the Jumper set to
the “A” position, which means that the switches and LEDs are connected
to the microcontroller. By setting the jumpers to the “F” position, the
switches and LEDs are connected to FPGA.

JP17

Rev 2 – The jumper is set towards the edge of the board, this connects to
the 4 MHz crystal. Connecting to other side will connect to the 18 MHz
crystal.
Rev3 and beyond – The position of the jumper is changed and it should be
set on the inner side to connect to the 4 MHz crystal. Connecting towards
the outer side of the board will connect to the 18 MHz crystal.

JP18

Has a Jumper Connected

JP19

Set to the RESET Position

JP20

Jumper connects the SER_EN pin of the AT17 device to the PORTE pin 7
of the microcontroller. By connecting this jumper, you can perform 2-wire
serial interface. Default is “Not Connected”

JP21

Jumper Connects CEO/A2 to V

CC

. Default is “Not Connected”

JP22

Jumper connects the write protect pins of the AT17 device to V

CC

.Default is

“Not Connected”

JP23

Rev4 and beyond – Jumper connects the write protect pins of the AT17
device to V

CC

. Default is “Not Connected”

ON/OFF (Sw14)

Power Switch. Default Position Off

Run /Prog

Switch Set to

Prog.

Содержание ATSTK94

Страница 1: ...e supplied with the kit which per forms a board test It is recommended to perform the board test when you receive the kit to test both your connections to the board and the board itself Install System Designer from the CD please refer to the Installation Licensing and Troubleshooting tutorial available on the Atmel web site at http www atmel com atmel products prod319 htm Request and Configure you...

Страница 2: ... button from the Output File pull down menu to indicate the out bst file under c training fpslic lab1 Select 1M from the EEPROM Density pull down menu Use the default options for the rest Press Start Procedure to program the Configurator If the utility has not been calibrated on a given PC the Clock Calibration dialog will be displayed when the Start Procedure button is clicked see Figure 2 For be...

Страница 3: ...bration can be performed again or at a later time by going to the Calibrate menu and selecting Calibrate now The out bst file can be overwritten If successful the results are shown in Figure 3 Figure 3 CPS Window Results After CPS reports successful completion you can switch from Prog to Run Your design starts to run The Alphanumeric will show a count sequence from 0 to 9 and from A to Z and will ...

Страница 4: ...d Prog Run in the wrong position or FATAL_ERROR CMD ack_sense timed out Double check the orientation of cable connected to evaluation board Any other failure would be related to the following Check to see that the Jumpers and Switches are in default positions see Table 1 The next area to check is the pinlocks In Figaro during the parts process make sure that you have selected to assign pinlocks Wi...

Страница 5: ...the jumper is changed and it should be set on the inner side to connect to the 4 MHz crystal Connecting towards the outer side of the board will connect to the 18 MHz crystal JP18 Has a Jumper Connected JP19 Set to the RESET Position JP20 Jumper connects the SER_EN pin of the AT17 device to the PORTE pin 7 of the microcontroller By connecting this jumper you can perform 2 wire serial interface Def...

Страница 6: ... TEL 1 408 436 4270 FAX 1 408 436 4314 Microcontrollers Atmel Corporate 2325 Orchard Parkway San Jose CA 95131 TEL 1 408 436 4270 FAX 1 408 436 4314 Atmel Nantes La Chantrerie BP 70602 44306 Nantes Cedex 3 France TEL 33 2 40 18 18 18 FAX 33 2 40 18 19 60 ASIC ASSP Smart Cards Atmel Rousset Zone Industrielle 13106 Rousset Cedex France TEL 33 4 42 53 60 00 FAX 33 4 42 53 60 01 Atmel Colorado Springs...