Flash Programming and Verification Characteristics
T
A
= 21°C to 27°C, V
CC
= 5.0
±
10%
Symbol
Parameter
Min
Max
Units
V
PP
(1)
Programming Enable Voltage
11.5
12.5
V
I
PP
(1)
Programming Enable Current
1.0
mA
1/t
CLCL
Oscillator Frequency
4
24
MHz
t
AVGL
Address Setup to PROG Low
48t
CLCL
t
GHAX
Address Hold After PROG
48t
CLCL
t
DVGL
Data Setup to PROG Low
48t
CLCL
t
GHDX
Data Hold After PROG
48t
CLCL
t
EHSH
P2.7 (ENABLE) High to V
PP
48t
CLCL
t
SHGL
V
PP
Setup to PROG Low
10
µ
s
t
GHSL
(1)
V
PP
Hold After PROG
10
µ
s
t
GLGH
PROG Width
1
110
µ
s
t
AVQV
Address to Data Valid
48t
CLCL
t
ELQV
ENABLE Low to Data Valid
48t
CLCL
t
EHQV
Data Float After ENABLE
0
48t
CLCL
t
GHBL
PROG High to BUSY Low
1.0
µ
s
t
WC
Byte Write Cycle Time
2.0
ms
Note:
1. Only used in 12-volt programming mode.
P1
P2.6
P3.6
P2.0 - P2.4
A0 - A7
ADDR.
OOOOH/1FFFH
SEE FLASH
PROGRAMMING
MODES TABLE
4-24 MHz
A8 - A12
P0
+5V
P2.7
PGM
DATA
PROG
V /V
IH
PP
V
IH
ALE
P3.7
XTAL 2
EA
RST
PSEN
XTAL 1
GND
V
CC
AT89C52
Figure 9. Programming the Flash Memory
P1
P2.6
P3.6
P2.0 - P2.4
A0 - A7
ADDR.
OOOOH/1FFFH
SEE FLASH
PROGRAMMING
MODES TABLE
4-24 MHz
A8 - A12
P0
+5V
P2.7
PGM DATA
(USE 10K
PULLUPS)
V
IH
V
IH
ALE
P3.7
XTAL 2
EA
RST
PSEN
XTAL 1
GND
V
CC
AT89C52
Figure 10. Verifying the Flash Memory
14
AT89C52