If the hot air is to be exhausted through the front panel of the Cool-stack II, 
installation is complete.  
 
If heated air is being exhausted through the top panel, and tubing is being used 
to carry the heated air away, connect it to the top tubing port now, using the 4" 
spring clamp supplied. If the tubing ends in an area in which temperature 
extremes, dust, moisture, odors, etc., are present, the use of a backdraft damper, 
as mentioned earlier, is recommended. Install it so that the swinging door closes 
reliably when the Cool-stack II is not operating. 
 
If the hot air is being exhausted through the rear panel, and tubing is being used, 
connect 2 lengths of 2" tubing to the rear panel ports (force the tubing into the 
fitting with a twisting motion) and run the tubing to the desired location; trim any 
excess. Backdraft dampers for this size tubing are not available. 
 
 

Содержание Cool-stack II

Страница 1: ...tack II are Two speed operation with automatic selection of speeds via a thermal probe and control assembly also controllable by external contact closure Sufficient depth 18 to pull heated air from the back of a rack where it is most often generated Six large 120mm 4 7 high quality fans for quiet ventilation Ability to exhaust heated air through the front rear or top or any combination of these fo...

Страница 2: ... odors etc these may travel down the tube to the rack A one way valve such as a check valve may be needed to prevent unpleasant surprises in the home theater Avoid running tubing to these areas if possible If needed a suitable check valve or backdraft damper is available from Active Thermal Management part number 03 103 02 IMPORTANT The use of a 2U or 3U vent panel near the bottom of the rack is h...

Страница 3: ...in figure 2 It can be installed with the opening closer to the front panel or further away either way is acceptable Proceed to step 1 of the installation section If exhausting through the rear panel remove the Cool stack II s front and top panels 4 phillips screws on the rear panel cover the inside of the front panel as in figure 1 and remove the plastic sheets covering the 2 rear panel exhaust op...

Страница 4: ...ucing equipment it may be preferable to position the thermal switch assembly in the air above the highest heat producer where it can sense the combined heat of all of the equipment Note that this arrangement will slow the response time of the Cool stack II as the hot equipment will have to heat a column of air which will then heat the thermal probe 4 Plug the thermal probe into the Thermal Switch ...

Страница 5: ...he 4 spring clamp supplied If the tubing ends in an area in which temperature extremes dust moisture odors etc are present the use of a backdraft damper as mentioned earlier is recommended Install it so that the swinging door closes reliably when the Cool stack II is not operating If the hot air is being exhausted through the rear panel and tubing is being used connect 2 lengths of 2 tubing to the...

Отзывы: