If exhausting through the top panel

, remove the front panel of the 

Cool-stack II and, using 
adhesive tape, fasten the sheet 
of black plastic film to the inside 
of the front panel at each end, 
blocking the vent openings as 

shown in figure 1. Remove the 
metal blank-out panel from the 
top of the Cool-stack II and 
replace it with the large exhaust port as shown in figure 2. (It can be 
installed with the opening closer to the front panel or further away; 
either way is acceptable.) Proceed to step 1 of the installation section. 

 
 

 

 

If exhausting through the rear panel

, remove the Cool-stack II's front 

and top panels (4 phillips screws on the rear panel), cover the inside of 
the front panel as in figure 1, and remove the plastic sheets covering 
the 2 rear panel exhaust openings. Replace the front and top covers 
(note that the return bend at the rear of the cover fits 

inside

 the 

chassis), and mount the 2 rear panel exhaust ports as shown in figure 
3. (Four screws are provided in the accessories box.) Proceed to step 
1 of the installation section. 

 
 
 

Figure 1 

Figure 2 

Содержание Cool-stack II

Страница 1: ...tack II are Two speed operation with automatic selection of speeds via a thermal probe and control assembly also controllable by external contact closure Sufficient depth 18 to pull heated air from the back of a rack where it is most often generated Six large 120mm 4 7 high quality fans for quiet ventilation Ability to exhaust heated air through the front rear or top or any combination of these fo...

Страница 2: ... odors etc these may travel down the tube to the rack A one way valve such as a check valve may be needed to prevent unpleasant surprises in the home theater Avoid running tubing to these areas if possible If needed a suitable check valve or backdraft damper is available from Active Thermal Management part number 03 103 02 IMPORTANT The use of a 2U or 3U vent panel near the bottom of the rack is h...

Страница 3: ...in figure 2 It can be installed with the opening closer to the front panel or further away either way is acceptable Proceed to step 1 of the installation section If exhausting through the rear panel remove the Cool stack II s front and top panels 4 phillips screws on the rear panel cover the inside of the front panel as in figure 1 and remove the plastic sheets covering the 2 rear panel exhaust op...

Страница 4: ...ucing equipment it may be preferable to position the thermal switch assembly in the air above the highest heat producer where it can sense the combined heat of all of the equipment Note that this arrangement will slow the response time of the Cool stack II as the hot equipment will have to heat a column of air which will then heat the thermal probe 4 Plug the thermal probe into the Thermal Switch ...

Страница 5: ...he 4 spring clamp supplied If the tubing ends in an area in which temperature extremes dust moisture odors etc are present the use of a backdraft damper as mentioned earlier is recommended Install it so that the swinging door closes reliably when the Cool stack II is not operating If the hot air is being exhausted through the rear panel and tubing is being used connect 2 lengths of 2 tubing to the...