Parts list

 – before proceeding, check that you have received all of the 

following:  

 

 

 

 

 

(1) Cool-stack II main chassis 

 

 

 

 

(1) Thermal probe 

 

 

 

 

 

(1) Power supply 

 

 

 

 

 

 

(1) Front panel 

 

 

 

 

Installation of the Cool-stack II

 rack-mount ventilator 

 
 

The Cool-stack II is a very powerful 2U high ventilator, well-suited for removing 
heated air from large rack installations. Some of the features of the Cool-stack II 
are: 
 

  Two-speed operation, with automatic selection of speeds via a thermal probe 

and control assembly; also controllable by external contact closure. 

 

  Sufficient depth (18") to pull heated air from the back of a rack, where it is 

most often generated.   

 

  Six large (120mm/4.7") high-quality fans for quiet ventilation. 

 

  Ability to exhaust heated air through the front, rear, or top, or any combination 

of these for maximum installation flexibility. (With optional exhaust kits)

 

 
 
 

General description: 
 

The Cool-stack II is an exhaust-mode ventilator. It will usually be located at the 
top of a rack, where its six 120mm fans will pull heated air up from the equipment 
below and exhaust it through its front panel. It is extremely quiet in low speed, 
and makes little noise in full speed.  
 

Содержание Cool-stack II

Страница 1: ...tack II are Two speed operation with automatic selection of speeds via a thermal probe and control assembly also controllable by external contact closure Sufficient depth 18 to pull heated air from the back of a rack where it is most often generated Six large 120mm 4 7 high quality fans for quiet ventilation Ability to exhaust heated air through the front rear or top or any combination of these fo...

Страница 2: ... odors etc these may travel down the tube to the rack A one way valve such as a check valve may be needed to prevent unpleasant surprises in the home theater Avoid running tubing to these areas if possible If needed a suitable check valve or backdraft damper is available from Active Thermal Management part number 03 103 02 IMPORTANT The use of a 2U or 3U vent panel near the bottom of the rack is h...

Страница 3: ...in figure 2 It can be installed with the opening closer to the front panel or further away either way is acceptable Proceed to step 1 of the installation section If exhausting through the rear panel remove the Cool stack II s front and top panels 4 phillips screws on the rear panel cover the inside of the front panel as in figure 1 and remove the plastic sheets covering the 2 rear panel exhaust op...

Страница 4: ...ucing equipment it may be preferable to position the thermal switch assembly in the air above the highest heat producer where it can sense the combined heat of all of the equipment Note that this arrangement will slow the response time of the Cool stack II as the hot equipment will have to heat a column of air which will then heat the thermal probe 4 Plug the thermal probe into the Thermal Switch ...

Страница 5: ...he 4 spring clamp supplied If the tubing ends in an area in which temperature extremes dust moisture odors etc are present the use of a backdraft damper as mentioned earlier is recommended Install it so that the swinging door closes reliably when the Cool stack II is not operating If the hot air is being exhausted through the rear panel and tubing is being used connect 2 lengths of 2 tubing to the...

Отзывы: