SAFETY  INFORMATION

 

11 

 

SAFETY  INFORMATION

 

 
 
 

Safeguards

 

 
 

To reduce the risk of electric shock, do not 
expose this product to rain or moisture.

 

 
 

If the wall plug does not fit into your local power 
socket, hire an electrician to replace your 
obsolete socket.

 

 
 

Do not modify the wall plug.

 

Doing so will void the warranty and safety 
features.

 

 
 

This equipment should be installed near the 
socket outlet and the device should be easily 
accessible in case it requires disconnection.

 

 
 
 

Precautions

 

 

FCC Regulations state that any unauthorized 
changes or modifications to this equipment not 
expressly approved by the manufacturer could 
void the user’s authority to operate this 
equipment.

 

 

Operate this product using only the included 
external power supply. Use of other power 
supplies could impair performance, damage the 
product or cause fires.

 

 

In the event of an electrostatic discharge, this 
device may automatically turn off. If this occurs, 
unplug the device, and plug it back in.

 

 

Protect and route power cords so they will not be 
stepped on or pinched by anything placed on or 
against them. Be especially careful of plug-ins, or 
cord exit points from this product.

 

 
 
 

Avoid excessive humidity, sudden temperature 
changes or temperature extremes.

 

 
 

Keep this product away from wet locations such 
as bathtubs, sinks, laundries, wet basements 
and swimming pools.

 

 
 

Use only accessories recommended by ATLONA 
to avoid fire, shock or other hazards.

 

 
 

Unplug the product before cleaning. Use a 
damp cloth for cleaning. Do not use cleaning 
fluid or aerosols, which could enter the unit and 
cause damage, fire or electrical shock. Some 
substances may also mar the finish of the 
product.

 

 
 

Never open or remove unit panels or make any 
adjustments not described in this manual. 
Attempting to do so could expose you to 
dangerous electrical shock or other hazards. It 
may also cause damage to your 

AT-VGA0505

Opening the product will void the warranty.

 

 
 

Do not attempt to service the unit. Instead 
disconnect it and contact your Authorized 
ATLONA reseller or contact ATLONA directly.

 

 
 
 

Содержание AT-VGA0505

Страница 1: ...AtlonA 5x5 Professional VGA with Audio Matrix Switch MODEL AT VGA0505 User s Manual Rev 0912...

Страница 2: ...age Contents 1 4 Specifications 2 5 Panel Description 3 5 1 Front Panel 3 5 2 Rear Panel 4 6 Channel Control 5 6 1 Software Control 5 6 2 ASCII Code Control 7 6 3 IR Remote Control 8 7 Installation 10...

Страница 3: ...bers television teaching rooms command centers and IT server rooms Power fail protection allows switcher to restore previous settings RS 232 communication control input allows to control switcher via...

Страница 4: ...selection IR remote control push button RS 232 control IR remote control Electro optical characteristics 25 Carrier frequency 36 40kHz Mechanical Housing Metal enclosure Dimensions L x W x H Model 1R...

Страница 5: ...X button to select input source channel in ascending sequence 4 W press the W button to select output display channel in descending sequence 5 X press the X button to select output display channel in...

Страница 6: ...els 10 OUTPUT1 OUTPUT5 Stereo audio output channels 11 INPUT1 INPUT5 Analog video input channels 12 OUTPUT1 OUTPUT5 Analog video output channels 13 5V DC Connect to 5V DC power supply unit 14 RS 232 C...

Страница 7: ...he matrix is detected a successful message window will show up Otherwise an error message will show up see below Please keep in mind that a successful connection can be established only if there is at...

Страница 8: ...l Input 2 Output 1 Input 3 Output 1 Input 2 Output 2 Input 3 Output 2 Input 2 Output 3 Input 3 Output 3 Input 2 Output 4 Input 3 Output 4 Input 2 Output 5 Input 3 Output 5 Channel 4 Input channel 4 on...

Страница 9: ...on by ASCII codes via RS 232 serial port Command Set for Windows Super Terminal COMMAND ACTION COMMAND ACTION COMMAND ACTION A1 Input 1 Output 1 C1 Input 1 Output 3 E1 Input 1 Output 5 A2 Input 2 Outp...

Страница 10: ...then use or to select the input channel Y 3 Once you reach the desire input output channel setting wait for 2 seconds and it ll be done Not in use Not in use Not in use Not in use Decrease CH Increase...

Страница 11: ...nput channel 1 to be shown on all 5 outputs 2 Press you want to have input channel 1 to be shown on all 5 outputs 3 Press you want to have input channel 1 to be shown on all 5 outputs 4 Press you want...

Страница 12: ...10 INSTALLATION...

Страница 13: ...s occurs unplug the device and plug it back in Protect and route power cords so they will not be stepped on or pinched by anything placed on or against them Be especially careful of plug ins or cord e...

Страница 14: ...MUM EXTENT PERMITTED BY APPLICABLE LAW ATLONA TECHNOLOGIES AND ITS SUPPLIERS DISCLAIM ALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY...

Страница 15: ...ord if your product is lost or stolen and helps ensure you ll receive notification of performance issues and firm ware updates At Atlona we respect and protect your privacy and assure you that your re...

Отзывы: