Local: 1-408-962-0515
Ethernet
For convenience, the UHD-PRO3-88M comes with DHCP on. This enables the matrix to be
connected to a network without knowing available IP addresses. If your network does not allow
dynamic IP addresses or if you are using the matrix with a TCP/IP control system, this feature may
be turned off and the IP address set using RS-232 commands, or webGUI.
To disable DHCP, use the following command: IPDHCP off. Once disabled, set the IP address using
the IPStatic command (e.g. IPStatic 192.168.1.56).
RS-232 captive screw connector is included. RS-232 pin out will be determined by the RS-232
cable and will connect as Rx
(receiver)
,
Tx
(transmitter)
,
and
(ground)
.
(See picture 1)
RS-232
Typical pin out:
2 - TX - Transmitter
3 - RX - Receiver
5 - GND - Ground
Pin out color will differ
per RS-232 cable.
1
5 4 3 2
9 8 7 6
1
RS-232
IR
Two types of female captive screw connectors have been included: 4
pin
(IR)
and 5 pin
(RS-232/IR)
.
RS-232/IR
IR
The wires of the emitter is marked to differenciate pin outs.
Signal (S)
Ground ( )
The IR emitter
(
AT-IR-CS-TX sold separately
)
has two wires: signal and ground. Signal will have a solid line
and ground will be blank. The IR emitter will plug into the IR OUT ports.
Note:
One AT-IR-CS-TX is included with the AT-UHD-EX-70C-RX (receiver) and AT-UHD-EX-100CE-RX (receiver).
There are two wires on the IR captive screw ready cable
(
AT-LC-CS-IR-2M sold separately
)
: signal and ground.
The signal wire is red and ground wire is black. The IR cable will plug into the IR IN ports and
connect to third party control systems.
Signal (S)
Ground ( )
S
S