AT-UHD-HDVS-300-KIT
34
Control page
The Web GUI
Key Lock
Click the
ON
button to lock all button on the front panel. Click the
OFF
button to unlock the buttons on the front
panel.
Factory Default
Click the
Reset Now
button to reset the AT-UHD-HDVS-300-KIT to factory-default settings.
Blink LED
Click the
Blink
button to start the POWER LED blinking. This feature is useful to identify the unit on a network, if
multiple units are being used.
RS-232 Control
Click this drop-down list to select the desired RS-232 control method. The AT-UHD-HDVS-300-KIT supports either
Control
or
Pass-Thru
mode. Refer to
for more information.
Setting
Description
Baud rate
Sets the baud rate. The following options are available: 9600, 19200, 38400, 56000,
57600, 115200.
Data bit
Sets the number of data bits used to represent each character of data. The following
options are available: 8 or 9.
Parity
Sets the parity bit, which can be included with each character to detect errors during
the transmission of data. The following options are available: None, Odd, or Even.
Stop bit
Sets the stop bit. Stop bits are sent at the end of each character, allowing the client
to detect the end of a character stream. The following options are available: 1 or 2.
Save / Cancel
Click the Save button to apply all changes. Click the
Cancel
button to abort changes.