19
atlona.com
Toll free: 1-877-536-3976
Local: 1-408-962-0515
Each command or feedback is terminated with a carriage return.
Note:
If the command fails or is incorrect the feedback should be “Command FAILED”
To help with zone troubleshooting the matrix will broadcast “#*PORTXX_[feedback]” when receiv-
ing any feedback from any zone.
RS-232 & TCP/IP Control Commands
The command codes are case sensitive, do not change capitalization, spacing, or lettering.
Command
Feedback
Description
PWON
PWON
Power on
PWOFF
PWOFF
Power off
PWSTA
PWx
Will display the power status of the matrix
Ex.
Power is on, feedback will be PWON
Version
Firmware #
Brings up the current firmware version
Type
Model #
Brings up the model information
Lock
Lock
Locks the front panel of the matrix so no buttons are active
Unlock
Unlock
Unlocks the front panel of the matrix, enabling the buttons again
All#
x1AVx1,x2AVx2,...
Resets all inputs to corresponding outputs
Ex.
input 1 to output 1, input 2 to output 2, input 3 to output 3, etc
x1$
x1$
Turns off output channel
Ex.
to turn off output 3 = x3$
x1All
x1All
Sets selected input to all outputs
Ex.
x3All would set input 3 to all
x1AVx2
Ex.
x3AVx7
x1AVx2
Ex.
x3AVx7
Switch input to output
Ex.
input 3 to output 7
x1AVx2,x3,x4
Ex.
x3AVx1,x4
x1AVx2,x3,x4
Ex.
x3AVx1,x4
Switch input to multiple outputs
Ex.
Switch input 3 to output 1 and 4
IROFF
IROFF
Disables the front panel IR receiver window
IRON
IRON
Enables the front panel IR receiver window
Statusx1
x7AVx1
Shows what input is connected to selected output
Status
x1AVx1,x2AVx2,
x3AVx4, ....
Displays which inputs are currently connected to which outputs
Save
Y
Ex.
Save2
Save
Y
Ex.
Save2
Saves I/O route settings for future use, preset options 0 to 8
Recall
Y
Ex.
Recall2
Recall
Y
Ex.
Recall2
Recalls saved I/O route settings for the chosen preset number
Clear
Y
Ex.
Clear2
Clear
Y
Ex.
Clear2
Erases the saved I/O route settings for the chosen preset number
Mreset
Mreset
Sets matrix back to the default settings