25
atlona.com
Toll free: 1-877-536-3976
Local: 1-408-962-0515
Command
Feedback
Description
IPCFG
IP Addr : x.x.x.x
Netmask : x.x.x.x
Gateway : x.x.x.x
IP Port : x
Displays IP address configure
IPQuit
IPQuit
Telnet Logout
IPAddUser [X] [Y]
IPAddUser [X] [Y]
IPAddUser [name] [password]. Add user of telnet.
If only command write “IPAddUser”, it will display all user list.
=> IPAddUser
IPDelUser [Y]
IPDelUser [Y]
IPDelUser [name]. Del user of telnet
IPDHCP [Y]
IPDHCP [Y]
IPDHCP [on/off/sta]. Set DHCP mode status and auto reset telnet.
Ex: Set DHCP mode is on => IPDHCP on
IPStatic [X] [Y] [Z]
IPStatic [X] [Y] [Z]
IPStatic [Address] [Netmask] [Gateway]. Set static IP address and
auto reset telnet.
Ex: Set static IP address is 192.168.1.1 255.255.255.0
192.168.1.254
=> IPStatic 192.168.1.1 255.255.255.0 192.168.1.254
IPPort [Y]
IPPort [Y]
IPPort [port]. Set telnet port and auto reset telnet
Ex: Set telnet port 80 => IPPort 80
IPLogin [Y]
IPLogin [Y]
IPLogin [on/off/sta]. Set telnet login status.
Ex: Set telnet login is on => IPLogin on
Broadcast [Y]
Broadcast [Y]
Broadcast [on/off/sta]. Broadcast switch.
Ex: Set broadcast mode is on => Broadcast on
IPTimeout [Y]
IPTimeout [Y]
IPTimeout [Sec]. Set telnet idle timeout time. Default is 2 minute.
Ex: Set telnet idle timeout 10 minutes => IPTimeout 600
Each command is terminated with a carriage return.
Feedback is terminated with a carriage return and line feed.
Note:
If the command fails or is incorrect the feedback should be “Command FAILED”
IP Commands
Zone output baud commands
(for display control)
RS232para1[baudrate,data-length,parity,stop-bit]
Example:
To change the output baud rate to 19200 use RS232para1[19200,8,0,1]
RS232zone1[command]
Once the switcher and zone output have been set up for the best communication, commands can
be sent to control the display. The commands will come from the user manual of the display or pro-
jector. The commands and any carriage returns/line feeds in the commands will need to be placed
in the bracket.
Example:
To turn the display or projector on if the command is PWRON carriage return, use the command:
RS232zone1[PWRON carriage return]
Note:
Use this command if the connected control system does not output 115200
Note:
Use this command if the connected display uses a different baud rate
Baud Rate
Default baud rate to control the switcher is 115200 and default baud rate to control the display or
projector is 9600.
Note:
For the display’s actual baud rate, refer to the owner’s manual
To change the baud rate of the switcher
(for switcher control)
or the zone output
(for display/source
control)
, the commands below will be needed
Switcher baud command
CSpara[baudrate,data-length,parity,stop-bit]
(data-length, parity, and stop-bit for switcher must be 8,0,1)
Example:
To change the baud rate to 38400 use
CSpara[38400,8,0,1]