3. Protocol Commands
To Switch Inputs to Outputs
SBI0XO0Y
- Where X is Output Number (1-1) and Y is Input Number (1-4)
Unit will respond with
SBUD0XOY
- Where X is Output Number (1-1) and Y is Input Number (1-4)
Example
: Send Input 4 to Output 1
SBI04O01
– Sending Command
SBUD04O1
– would be the feedback command which switcher will send back to the control system to confirm
the input change
4. RS-232 Serial Commands
Power OFF command -
SBSYSMOF
Power ON command -
SBSYSMON
Unit will respond with:
Unit is in Standby -
SBALOFAK
Unit is no longer in Standby -
SBALONAK
Example
: Put Unit in Standby (Soft Power)
SBSYSMOF
Switchers will feedback with
SBALOFAK
5. Front Panel Lock
Note: Hard resetting the unit will unlock the Front Panel controls
.
Lock Front Panel:
SBSYSMLK
– When locked, changes can only be made via RS232
Unlock front panel:
SBSYSMUK
Unit will respond with:
SBSYSLOK
- Front Panel has been locked
SBSYSULK
- Front Panel has been Unlocked
SBALLRST
- Reset every output to Input 1
Unit will respond with
SBRSTACK