www.atlona.com | toll free:
1-877-536-3976
For International: 1-
408-962-0515
7
2. IR Extender Package
RS 232
1. RS-232 Serial Interface
RS-232 serial interface allows connecting a control system or a computer to it for controlling the switcher
Pin
RS-232
Definition
1
-
Not used
2
Tx
Transmitter
3
Rx
Receiver
4
-
Not used
5
GND
Ground
6
-
Not used
7
-
Not used
8
-
Not used
9
-
Not used
2. RS232
The Atlona switcher is featured with RS232 control port which allows users to control the switch though a con-
trol system or from the computer.
The serial communication parameters are 9600 baud rate, 8 bit, No Parity and 1 stop bit
When the unit recognizes a complete command it will perform the requested action - there is no delimiter char
-
acter required.
Note: The unit does not send out a feedback message when a value is changed from the front panel or by IR control. If
the switcher needs to be controlled though front panel in addition to the RS232 control, user should regularly verify the
unit’s status to ensure the control system accurately reflects the current settings.
1
5
6
9