7.3.1 REFILLING THE HYDRAULIC CIRCUIT WITH OIL
Figure 7.3-A
The hydraulic circuit needs to be refilled with oil after continuous use, and when you notice a reduction in the tool stroke.
Proceed as follows (see Picture 7.3-A):
• Disconnect the airline from the tool inlet.
• Unscrew the manostat (A) with relevant wrench 54.
• Remove cap together with relevant washer 27.
• Put the tool in horizontal position and slowly pour in the hydraulic oil (ISO VG 32 type) 50 until the circuit is full.
• Screw cap back on, together with relevant washer 27
• Connect the tool to compressed airline and start a couple of idle cycles (do not pull trigger), unscrew cap 27, and make
sure the circuit is full of oil and no air bubbles should be present.
• Wear gloves when managing the oil
Do not throw the old oil outdoors. Dispose of it at your local waste disposal center.
Warning! If you accidentally spill oil on your skin, wash and rinse thoroughly with water and alkaline soap.
7.3.2 PARTS SUBJECT TO WEAR
Periodically check the state of wear of the rubber base, as this ensures tool stability. To order a new base from Rivit
S.r.l., please indicate the year/serial number of the tool (see section 4.5).
Periodically check the state of wear of the screws and of the heads. If necessary, replace them as indicated in section
6.2.
Spare parts should be ordered exclusively from Rivit S.r.l., specifying the codes listed in section 3.1.
50
(A)
27
Содержание RIV939P
Страница 1: ...RIV939P HYDROPNEUMATIC TOOL FOR RIVET NUTS FROM 4 40 TO 1 2 AND M3 TO M12 OPERATING INSTRUCTIONS ...
Страница 2: ...2 PennEngineering www pemnet com Instruction Manual RIV939P ...
Страница 6: ...Instruction Manual RIV939P ...
Страница 56: ...56 PennEngineering www pemnet com Instruction Manual RIV939P 2020 Rev 1020 ...