39
WARNING
The information in the POSSIBLE REMEDY column requires work to be performed by
specialist technicians or other authorised people who must always work using the
Personal Protective Equipment indicated in the INSTALLATION manual. In some cases,
this work can be performed by a normal operator.
ERROR CAUSE
POSSIBLE REMEDY
Black
The wheel balancer does not
switch on.
1. Check the machine is properly connected to the mains power
supply.
2. Check the fuses on the power board and replace if necessary.
3. Replace the CPU board.
Err. 1
No rotation signal.
1. Use the self-diagnostics function to check the encoder.
2. Replace the encoder.
3. Replace the CPU board.
Err. 2
Speed too low during
detection. During the
unbalance measurement
revolutions, the wheel speed
has fallen to below 42 rpm.
1. Make sure that a vehicle wheel is mounted on the wheel balancer.
2. Use the self-diagnostics function to check the encoder.
3. Disconnect the piezo connectors from the board and do a spin
(if no error is detected, replace the piezo sensors).
4. Replace the CPU board.
Err. 3
Unbalance too high.
1. Check the wheel dimensions setting.
2. Check the detection unit connections.
3. Run the machine calibration function.
4. Mount a wheel with more or less known unbalance (less than
100 grams) and check the response of the machine.
5. Replace the CPU board.
Err. 4
Rotation in opposite
direction.
1. Use the self-diagnostics function to check the encoder.
2. Check the encoder bearing/spring.
Err. 5
Guard open
The [START] pushbutton was
pressed without first closing
the guard.
1. Reset the error.
2. Close the guard.
3. Verify the function of the protection switch.
4. Press the [START] button.
Err. 7
Err. 8
Err. 9
NOVRAM parameter read
error
1. Switch off the machine and wait for at least ~ 1 min;
re-start the machine and check it works properly.
2. Repeat machine calibration.
3. Replace the CPU board.
Err. 11
Too high speed error.
The average spinning speed is
more than 240 rpm.
1. Use the self-diagnostics function to check the encoder.
2. Replace the computer board.
Err.14
Err.15
Err.16
Err.17
Err.18
Err. 19
Unbalance measurement
error.
1. Use the self-diagnostics function to check the encoder.
2. Check the detection unit connections.
3. Check the machine earthing connection.
4. Mount a wheel with more or less known unbalance (less than
100 grams) and check the response of the machine.
5. Replace the CPU board.
Err. 20
Wheel still. The wheel must
remain still for more than one
second after START.
1. Use the self-diagnostics function to check the encoder.
2. Check the connections on the power board.
3. Replace the CPU board.
Err. 21
Motor on for more than 15
seconds.
1. Use the self-diagnostics function to check the encoder.
2. Check the connections on the power board.
3. Replace the CPU board.
Err. 22
Maximum number of spins
possible for the unbalance
measurement has been
exceeded.
1. Check that a vehicle wheel has been mounted on the wheel
balancer.
2. Use the self-diagnostics function to check the encoder.
3. Replace the computer board.