10.3 OPPOSITE WEIGHT FUNCTION (OPF)
The normal balancing condition requires the correction weights to be applied at the top (12 o’clock) when the symbol
is displayed:
If “OPPOSITE WEIGHT FUNCTION (OPF)” is enabled, the phase displays also indicate the weight application
position at the bottom (6 o’clock) to facilitate cleaning the rim and the relative application of adhesive weights. The
symbol used is:
10.4 Self-diagnostics
The machine can perform self-diagnostics to check the LED’s on the control panel and make sure the encoder
reads correctly.
To perform this operation, view the SETUP menu.
In the self-diagnostics sequence, all the LED’s on the panel light up for a few seconds in order to check operation.
When the LED’s go out, the machine automatically moves on to the encoder reading phase. When the wheel is turned
manually (forwards and backwards), the display shows its exact position. The value lies between 0 (zero) and 255.