6
PennEngineering • www.pemnet.com
Instruction Manual - RIV 938S
RECEIVERS
The manual herein has been written for both the operators and the technicians enabled to service the tool.
Operators must not carry out jobs reserved to service and/or qualified technicians.
Rivit S.r.l. is not liable for any damage deriving from the failed observance of this rule.
PLACING OF THE MANUAL
This instruction manual must be kept near the tool, inside a dedicated container and, above all, away from liquids or
anything else that may compromise its legibility.
VIBRATION
When used correctly, the tool does not produce any dangerous vibration.
NOISE LEVEL
The tool is designed and manufactured in such a way that the noise level is very low. The weighed equivalent continu-
ous acoustic pressure level A in the operator position is indeed below 80 dB (A).
This information can allow the tool user to better evaluate the possible risks of danger.
TECHNICAL DATA
The following table provides the technical data and features of the tool, to which you must refer when contacting the
ATLAS
®
Technical Assistance Department at PennEngineering.
AIR WORKING PRESSURE
90 PSI / 6 BAR
MAX AIR PRESSURE
70 to 100 PSI / 5 to 7 BAR
AIR CONSUMPTION
305.1 cu. in. @ 90 PSI
PER CYCLE
5 liters @ 6 BAR
MAX STROKE
.256” / 6.5 mm
MAX AXIAL PULLING LOAD
3147 lbs. @ 90 PSI
14 kN @ 6 BAR
MOTOR SPEED (SPIN ON)
1600 rpm
MOTOR SPEED (SPIN OFF)
2000 rpm
WEIGHT
3.7 lbs. / 1.7 kg
VIBRATIONS
< 2.5 m/s2
NOISE LEVEL
76 dB (A)
TECHNICAL DATA AND FEATURES