background image

 

– 9 – 

AtlasSound.com

Specifications are subject to change without notice.

Owner’s Manual

AA240 Mixer Amplifier

1601 Jack McKay Blvd. • Ennis, Texas 75119  U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

12.  Input 1 Sens 

This control adjusts how sensitive the mute send circuitry on INPUT 1 reacts. Setting the control fully counter clockwise will lower 
the sensitivity and a higher amplitude signal will be required at INPUT 1 to trigger the mute send circuits. Fully clockwise will raise 
the sensitivity of the mute circuits, where a lower amplitude signal will trigger a mute send. Careful calibration of this control may 
be required to fully utilize the mute circuits’ capabilities. Adjustment of this control should occur after the input trim (13) for channel 
1 is set.

13.  Inputs 1-5 Trim 

These variable controls allows fine tuning of the gain of INPUTS 1 – 5. There is 20dB of variable gain available. The trim only applies 

when the input is set to the “Mic” position on the dipswitch. 

14.  Zone 2 Level 

This rotary control will vary the signal level at the Zone 2 output terminals. Fully counter-clockwise (0) is off; fully clockwise (10) is 
the maximum output level. The Zone 2 output gets its signal from INPUT 6.

15.   VCA  

Remote location of the level control can be accomplished via the VCA control port. You can control the overall level (Master) or 

just Input 6. This selection is made via Dipswitch “B” position #8. Connect the two leads from the optional remote volume control 

(AAVC-10K) to these terminals. This remote level control is POST Master and Input 5 Level Controls. Set the system's maximum 
levels using the amplifier level controls and then use the remote VCA potentiometer as an attenuator from the maximum levels set. 
See the VCA setup section for instructions on wiring the potentiometer.

16. Remote Mute 

 

 The Remote Mute feature is useful when the background system needs to be muted from a remote location. When shorting the 
Remote Mute terminals together, (G) to (M), the assigned channels will be muted. 

 

Note:  Input 1 cannot be VOX or remote muted at anytime. Dipswitches 2-5 settings determine which inputs are to receive the 

Mute trigger. To trigger the mute it is common to use an external contact closure or switch on a microphone.

17.   Zone 2 Output – 600

Ω

 

The 600

Ω

 1.5V (Zone 2 Out) output is typically connected to a PBX MUSIC ON HOLD port, also known as MOH. The ZONE 2 out

-

put gets its signal from INPUT 6.

18.   Zone 2 Output – 1 Watt 8

Ω

 

The 8

Ω

 1W Zone 2 output can drive an external 8

Ω

 speaker, and is taken Pre input 6 gain control. Use the 1W 8

Ω

 terminals for con-

nection to an external speaker.

19.  Bridge In/Out 

Certain installations have the need to combine one or more mixers together. These mixers may be in different rooms of an install 
but have the need to share a page or music throughout the installation. These terminals provide a way to send and receive bal-

anced line level signals from the internal mix bus of the AA240. The “BRIDGE IN/OUT” feature is PRE Tone Controls and Low Cut 
Filter the Bridge In/Out feature allows you to send and receive a balanced signal. This is important for allowing longer distances 

between the mixers. 

 

Note:  This function should ONLY be used with other Atlas Sound mixers that have this feature. The Send and Receive signals are 

combined through the same terminals. To activate this feature, see number 20 Bridge Select.

VCA

In/Out

Bridge

Sel

Zone 2 Out

Ω

1W 8

Ω

600

Remote

Mute

Input 2

Trim

Input 3

Trim

Input 5

Input 6

Off
On

Off
On

Off
On

Off
On

Input 2

On

Off

Line

Mic

Line

Mic

Line

Mic

Sens

Input 1

Input 2

Input 3

Input 4

Input 5

Phantom

On

Off

Input 6

1

2

3

4

5

300mV

100mV

6

7

Master

Line

Mic

Mic

Tel/Line

Off
On

Mute Rcv

Input 6 Input 5 Input 4 Input 3

VCA

5

1

2

3

4

8

Low Cut 

6

Input 1

Sens 

Input 1

Trim

Input 4

Trim

Input 5

Trim 

Zone 2

Level

B

A

Line Out

Speaker Output 240W

Ω

100V

70V

25V

4

Com

+

+

G

+

R

L

Pre Out

Pwr In

Tape Out

Input 6

Input 4

Input 3

Input 2

Input 1

Unswitched Outlet 

120V  

~

  60Hz 

Max 500W

Outlet Breaker 

125V  

~

  4A 

Push Reset

G

+

G

+

G

+

G

+

+

G

120V AC 60Hz 700W

1601 Jack McKay Blvd., Ennis, TX 75119 

(800) 876-3333 AtlasSound.com

CLASS 2 WIRING

Содержание AA240

Страница 1: ...d com Specifications are subject to change without notice Owner s Manual AA240 Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 AA240 Atlas Sound Mixer Amplifier ...

Страница 2: ...nstructions 3 Introduction Features and Applications 6 Front Panel Description 7 Rear Panel Description 8 11 Quick Start Examples 12 14 Wiring the AA240 15 Load Consideration and Overload LED 15 Measuring Speaker Loads 16 Measuring 25V 70 7V Distributed Speaker Systems 16 Security Covers Option 17 Wiring the AAVCC 10K VCA Potentiometer 17 AA240 Block Diagram 18 Optional Input Transformer Installat...

Страница 3: ...oving the cart device combination to avoid injury from tip over 13 Unplug this device during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the device has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the device the device has been ex...

Страница 4: ...may result When unplugging the cord from the wall grasp the plug NOT the cord Never install this device in humid or dusty locations nor in direct sunlight near sources of heat or in areas where sooty smoke or steam are present Fire and electric shock may result Keep all sides of the device at least 31 2 away from objects that may obstruct air flow to prevent the unit s internal temperature rise Am...

Страница 5: ...ical storm electric shock may result Never exceed the wattage on the product when connecting equipment Fire and or property damage may result Operate the device only with the voltage specified on the unit Fire and or electric shock may result if a higher voltage is used Do not modify kink or cut the power cord Do not place the power cord in close proximity to heaters and do not place heavy objects...

Страница 6: ...nstaller in today s commercial business audio environment Features Zone 1 Output 240 Watts Zone 2 Output 1 Watt 8Ω or 1 5V 600Ω Inputs 1 5 Mic Line Switchable Input 6 Line Level Only Input 1 has VOX Send Inputs 2 6 have Switch Selectable Mute Receive 2 Tape and 2 Line Outputs Remote VCA Selectable INPUT 6 or MASTER Switch Selectable Bridge In Out Bus Allows Amplifier Combining Pre Amp Out Power Am...

Страница 7: ...e speakers 5 Signal LED This LED will assist you in setting gain structure into the amp With a source connected to the amp and playing turn up the chan nel gain control until this LED just starts to flash green Once all the sources connected are playing the SIGNAL LED may be on solid This condition is normal 6 Master Gain Control The MASTER GAIN CONTROL will raise or lower all the input channels t...

Страница 8: ... and Mic modes In some Line source input application the Phantom Power may cause popping This can be corrected by adding a 10uf 100uf 50V electrolytic capacitor in series with the input Contact Atlas for an application note Dipswitch 8 When set to the Master position the VCA control port acts as an overall system remote volume control adjusting all the input channels present on the master section ...

Страница 9: ...gether G to M the assigned channels will be muted Note Input 1 cannot be VOX or remote muted at anytime Dipswitches 2 5 settings determine which inputs are to receive the Mute trigger To trigger the mute it is common to use an external contact closure or switch on a microphone 17 Zone 2 Output 600Ω The 600Ω 1 5V Zone 2 Out output is typically connected to a PBX MUSIC ON HOLD port also known as MOH...

Страница 10: ...ng a 10uf 100uf 50V electrolytic capacitor in series with the input Contact Atlas for an application note 23 Input 6 INPUT 6 consists of a pair of stereo summing line level inputs Connect unbalanced audio outputs here such as CD players or audio from DVD players 24 Line Out A B The LINE OUT connector is useful for providing unbalanced line level signal to another amplifier or other external device...

Страница 11: ...otal load impedance of no less than 2 6Ω 70 7V Connect to transformer coupled 70 7V loudspeakers with a total load impedance of no less than 21Ω 100V Connect to transformer coupled 100V loudspeakers with a total load impedance of no less than 41 6Ω 29 Power Cord Connect the power cord to 120VAC only Serious damage may result if accidentally connected to other line voltages 30 Unswitched Outlet The...

Страница 12: ...2 output to the MOH input on your telephone Adjust the Zone 2 Output level as needed Connect a wall mount volume control Atlas Part Number AAVC 10K to the terminals marked VCA Set Dipswitch B 8 VCA to Master Dipswitch Settings Dipswitch 1 Off Set To The Required Gain Dipswitch 2 Off Not Affected Dipswitch 3 Off Not Affected Dipswitch 4 Off Not Affected Dipswitch 5 Off Line Dipswitch 6 On Mic Dipsw...

Страница 13: ... and DPST switch see drawing for clarity controls the background music level and turns the music on or off in each room For emergency evacuation pur poses a signal from the hotel s fire alarm system is connected to channel 1 of both amplifiers with the mute sensitivity adjusted as needed All other channels are set for mute receive and will mute when the siren tone is present on channel 1 Dipswitch...

Страница 14: ... Type Dipswitch 8 Master Dipswitch 1 On Dipswitch 2 On Dipswitch 3 On Dipswitch 4 On Dipswitch 5 On Dipswitch 6 On 10 0 10 0 0 10 On Off Input 6 Input 5 Input 4 Input 3 Input 2 10 0 10 0 10 0 Bass Treble 0 10 Input 1 Master Power Power Limit Peak Signal VCA In Out Bridge Sel Zone 2 Out Ω 1W 8 Ω 600 Remote Mute Input 2 Trim Input 3 Trim Input 5 Input 6 Off On Off On Off On Off On Input 2 On Off Lin...

Страница 15: ...ED on damage may occur Refer to page 16 of manual for protect conditions In most situations when the LED is illuminated it means the speaker system load to the amp is lower than what the amp is rated for This usually is detected when you first are setting up the system Below are a few load conditions to check for if the Protect light is on 1 Connected to the wrong speaker terminal Always check the...

Страница 16: ...volume controls There are several Audio Impedance meters on the market if you need to buy one we suggest going to MCM Electronics or search the internet for Audio Impedance Meter Measuring 25V 70 7V Distributed Speaker Systems Large distributed systems typically utilize 25 2V or 70 7V transformers 50V and 100V in Europe to greatly ease the connection of multiple speakers and facilitate long cable ...

Страница 17: ...the pot terminals to the terminals marked VCA on the back of the amp 10 0 10 0 0 10 On Off Input 6 Input 5 Input 4 Input 3 Input 2 10 0 10 0 10 0 Bass Treble 0 10 Input 1 Master Power Power Limit Peak Signal VCA In Out Bridge Sel Zone 2 Out Ω 1W 8 Ω 600 Remote Mute Input 2 Trim Input 3 Trim Input 5 Input 6 Off On Off On Off On Off On Input 2 On Off Line Mic Line Mic Line Mic Sens Input 1 Input 2 I...

Страница 18: ...MIC MUTE PRE TRIM CHANNEL 3 IN 3 LEVEL LINE PHANTOM MIC MUTE PRE TRIM CHANNEL 4 IN 4 LEVEL LINE PHANTOM MIC MUTE PRE TRIM CHANNEL 5 IN 5 LEVEL LINE PHANTOM MIC MUTE PRE TRIM IN 6 LEVEL 100mV 300mV MUTE PRE AMP IN PRE PRE BRIDGE IN OUT SELECT ACTIVATE MASTER LEVEL LINE OUT A B 70 7V ZONE 2 LEVEL VCA VCA BASS TREBLE FILTER Input 6 Off On Off On Off On Off On Input 2 On Off Line Mic Line Mic Line Mic...

Страница 19: ...1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Optional Input Transformer Installation Contact Atlas Sound at 1 800 876 3333 for price and availability INPUT 1 TRANSFORMER JUMPERS INPUT 1 OPTIONAL TRANSFORMER SOCKET XFMER IN XFMER BYPASS XFMER IN XFMER BYPASS p n AAIT 600 ...

Страница 20: ...Distortion 1 at rated power 1kHz Sensitivity Input 1 Line Tel 316mV 10dBV 10kΩ 600Ω with optional transformer Mic 316mV 3 16mV 50dBV 70dBV Inputs 2 5 Line 316mV 10dBV 10kΩ Mic 316mV 3 16mV 50dBV 70dBV Input 6 Line 300mV 100mV 10dBV 20dBV Selectable Outputs Main Transformer coupled balanced 4Ω 25V 70V and 100V Zone 2 8Ω Unbalanced 1W Zone 2 600Ω Balanced 1 5V Signal To Noise Ratio Mic 55dB Line 55d...

Страница 21: ... 21 AtlasSound com Specifications are subject to change without notice Owner s Manual AA240 Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Notes ...

Страница 22: ...AtlasSound com 22 Specifications are subject to change without notice Owner s Manual AA240 Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Notes ...

Страница 23: ... 23 AtlasSound com Specifications are subject to change without notice Owner s Manual AA240 Mixer Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Notes ...

Страница 24: ...rms of this warranty All warranty returns must comply with our returns policy set forth below When products returned to Atlas Sound do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs for material and labor unless there is included with the returned product s a written request for an estimate of repair costs before any nonwarranty work is perfor...

Отзывы: