Connect Logic and Relay I/O
The IP100 provides eight (8) logic sensor inputs that can be used to trigger announcements, indicate a fault with external equipment or mute the
system, for example. Also there are eight (8) dry contact outputs which can provide control to external systems or indicate a system status, for
example. As required for the application, attach logic input lines and relay output lines to the terminal blocks provided, as shown in the images below.
Each logic input is isolated and terminations are made by connecting the signal to the + terminal while using the – terminal for the return path to the
signaling device. Pins 5 and 10 on each connector provide a reference to chassis ground. Refer to the image below for details on the logic and relay