Atlas fan company PA3-CR Скачать руководство пользователя страница 12

10

Figure 20

Figure 18

Figure 19

ON ECE

1 2 3 4

ON

D

ON ECE

ON

D

Restore power to ceiling fan and test for proper 

operation.

A. I, II, III, IV, V and VI button:
These six buttons are used to set the fan speed as 
follows:
I = minimum speed
II = low speed
III = medium low speed
IV = medium speed
V = medium high speed
VI = high speed

B.         button:
This button turns the fan off.

C.          Reverse button:
This button is to control fan direction

D.          Light button
This button is to control light. Switch the “D” and “ON” 
dip switch on the back of transmitter to decide the light 
in “ON/OFF” or “Dimmable” condition.

E. SET code setting button:
Your DC brushless motor is equipped with automatically 
learned type remote control and a wall control. If two 
fans or more in a house, it is recommended that you not 
use the factory code settings. Change codes setting to 
any other combination of dip switch setting to avoid fan 
interference issues, but users need to do control setting 
process as below once the code setting is changed. 
Please refer the "D" "SET" code setting button section. 
Follow the below steps to set the remote control:
The auto learning function will only mandate within 60 
seconds when turning the fan’s AC power ON.

a) Select desired frequency from the transmitter.

b) From the wall or remote transmitter, press the “SET” 
button, and hold the “SET” button for over 10 seconds. 
Once the receiver has detected the frequency, the light 
will flash twice, and the fan will automatically begin to 
operate and start to rotate in the counterclockwise 
direction and on the highest RPM for 3 minutes. When 
counter clockwise rotation has finished, the fan will 
automatically reverse to clockwise direction again to the 
highest RPM for 3 minutes. Fan will shut off when the 
self calibration test has finished. The total self calibration 
test will last about 6 minutes.

11. PROGRAMMING YOUR 

FAN AND OPERATING 
THE REMOTE CONTROL 
AND WALL CONTROL

Before programming takes place, fan must be fully 

assembled and mounted to the ceiling with blades 

attached.

 

You must  also  choose  which  control you 

will be using for programming the fan, the  remote  

or  the  wall  control. No other wall control should be 

used with this fan but that which was included.  

Using another wall control other than ours will 

damage your fan and void your warranty. 

Install one 23A/12V battery (included). To prevent 
damage to transmitter, remove the battery if not used 
for long periods of time (Fig. 18 & 19)

Содержание PA3-CR

Страница 1: ...S Patricia 60 52 or 42 CEILING FAN Please do not use any electric or battery powered tools in the assembly and installation of this or any Matthews Fan Company product FAN RATING AC 120V 60Hz FOR DAMP...

Страница 2: ...Electric Connections Finishing the Installation Attaching the Fan Blades Attaching the Mounting Plate Installing the Light Kit Programming Your Fan and Operating the Remote Control and Wall Control O...

Страница 3: ...s l Wall transmitter incl 2 mounting screws and 3 wire nuts m Wall plate incl 1 face plate and 2 mounting screws n 12V batteries 2 o Package hardware 1 Mounting hardware wood screws 2 screws 2 lock wa...

Страница 4: ...an press the reverse button while the fan is running 7 Avoid placing objects in the path of the blades 8 To avoid personal injury or damage to the fan and other items be cautious when working around o...

Страница 5: ...35lbs or less Do not use plastic outlet boxes Figures 1 2 and 3 are examples of different ways to mount the outlet box Note The Fig 3 are for use for downrod style only Note You may need a longer down...

Страница 6: ...les at the bottom of the downrod with the holes in the collar on top of the motor housing Carefully insert the hitch pin through the holes in the collar and downrod Be careful not to jam the pin again...

Страница 7: ...ntrol 1 Connect the fan supply black wire to the black household supply wire as shown in Figure 9 2 Connect the neutral fan white wire to the white neutral household wire Fig 9 3 Connect the fan groun...

Страница 8: ...ect the fan ground wire green to the household ground wire 4 Check that the two plugs large and small are making proper contact One plug is small with only a single wire connection The second plug is...

Страница 9: ...crews Note Adjust the canopy screws as necessary until the canopy and canopy cover are snug Warning Make sure tab at bottom of hanger bracket is properly seated in groove of hanger ball before attachi...

Страница 10: ...lades Tighten each screw and make sure the blade is straight NOTE This fan is supplied with two types of blades for installation Please reference the important diagram Fig 15 when attaching your fan b...

Страница 11: ...ree studs on the glass shade assembly and secure it to the mounting plate until snug 5 If installing the optional metal light cover make sure is securely tighten NOTE The metal light cover included wi...

Страница 12: ...unction will only mandate within 60 seconds when turning the fan s AC power ON a Select desired frequency from the transmitter b From the wall or remote transmitter press the SET button and hold the S...

Страница 13: ...l continue to retain the last set frequency and calibration set even when the AC power is shut off If the frequency is changed the self calibration test will occur again F D and ON dip switch The ON s...

Страница 14: ...ade bracket to the motor hub is tight 3 Make sure wire nut connections are not rubbing against each other or the interior wall of the switch housing CAUTION Make sure main power is off 4 Allow a 24 ho...

Страница 15: ...ot be responsible for how the product is installed or used Before purchase and use of a product please review the product application and national and local codes and regulations and be sure that the...

Отзывы: