Atlas fan company IR3-TB-BW-52 Скачать руководство пользователя страница 4

1.  To reduce the risk of electric shock, insure 

electricity has been turned off at the circuit 
breaker or fuse box before beginning.

2.  All wiring must be in accordance with the 

National Electrical Code and local electrical 
codes. Electrical installation should be 
performed by a qualified licensed electrician.

3.  

WARNING:

 To reduce the risk of electrical 

shock and fire, do not use this fan with any 
solid-state fan speed control device.

4.  

WARNING:

 To Reduce The Risk Of Fire, 

Electric Shock, Or Personal Injury, Mount To 
Outlet Box Marked Acceptable for Fan 
Support of 15.9 kg (35 lbs) or less And Use 
Mounting Screws Provided With The Outlet 
Box. Most outlet boxes commonly used for 
the support of lighting fixtures are not 
acceptable for fan support and may need to 
be replaced, consult a qualified electrician if 
in doubt.

5.   The fan must be mounted with a minimum of 

7 feet clearance from the trailing edge of the 
blades to the floor.

6.   To operate the reverse function on this fan, 

press the reverse button while the fan is 
running.

7.  Avoid placing objects in the path of the 

blades.

8.   To avoid personal injury or damage to the fan 

and other items, be cautious when working 
around or cleaning the fan.

9.  Do not use water or detergents when cleaning 

the fan or fan blades.  A dry dust cloth or lightly 
dampened cloth will be suitable for most 
cleaning.

10. After marking electrical connections, spliced 

conductors should be turned upward and 
pushed carefully up into outlet box. The 
wires should be spread apart with the 
grounded conductor and the equipment 
-grounding conductor on one side of the 
outlet box.

11.  Electrical diagrams are reference only. Light 

kit that are not packed with the fan must be 
UL Listed and marked suitable for use with 
the model fan you are installing. Switches 
must be UL General Use Switches. Refer to 
the Instructions packaged with the light kits 
and switches for proper assembly.

2

3. SAFETY RULES

WARNING

TO REDUCE THE RISK OF PERSONAL 

INJURY, DO NOT BEND THE BLADE 

BRACKETS (ALSO REFERRED TO AS 

FLANGES) DURING ASSEMBLY OR AFTER 

INSTALLATION. DO NOT INSERT OBJECTS IN 

THE PATH OF THE BLADES.

Содержание IR3-TB-BW-52

Страница 1: ...AVE THESE INSTRUCTIONS Irene 60 52 or 42 CEILING FAN Please do not use any electric or battery powered tools in the assembly and installation of this or any Matthews Fan Company product FAN RATING AC...

Страница 2: ...ions Hanging the Fan Attaching the Fan Blades Make the Electric Connections Finishing the Installation Programming Your Fan and Operating the Remote Control and Wall Control Operating Your Fan Care of...

Страница 3: ...ts h Wall plate incl 1 face plate and 2 mounting screws i 12V batteries 2 j Package hardware 1 Mounting hardware wood screws 2 screws 2 lock washers 2 washers 2 star washers 2 wire nuts 3 2 Blade atta...

Страница 4: ...e function on this fan press the reverse button while the fan is running 7 Avoid placing objects in the path of the blades 8 To avoid personal injury or damage to the fan and other items be cautious w...

Страница 5: ...ight of the fan 15 9 kgs 35lbs or less Do not use plastic outlet boxes Figures 1 2 and 3 are examples of different ways to mount the outlet box Note You may need a longer downrod to maintain proper bl...

Страница 6: ...g 6 3 Secure the hanger bracket to the ceiling outlet box using screws and washers included with your outlet box Fig 7 Ceiling hanger bracket Mounting screws supplied with electrical box Hook Electric...

Страница 7: ...ownrod Insert the lock pin through the hole near the end of the hitch pin until it snaps into its locked position Fig 8 Warning Caution Failure to properly install lock pin as noted in step 6 could re...

Страница 8: ...l 1 Connect the fan supply black wire to the black household supply wire as shown in Figure 10 2 Connect the neutral fan white wire to the white neutral household wire Fig 10 3 Connect the fan ground...

Страница 9: ...ect the fan ground wire green to the household ground wire 4 Check that the two plugs large and small are making proper contact One plug is small with only a single wire connection The second plug is...

Страница 10: ...lign the circular hole on canopy with the remaining hole on the hanger bracket secure by tightening the two set screws Note Adjust the canopy screws as necessary until the canopy and canopy cover are...

Страница 11: ...a Select desired frequency from the transmitter b From the wall or remote transmitter press the SET button and hold the SET button for over 10 seconds Once the receiver has detected the frequency the...

Страница 12: ...l continue to retain the last set frequency and calibration set even when the AC power is shut off If the frequency is changed the self calibration test will occur again E D and ON dip switch The ON s...

Страница 13: ...lade bracket to the motor hub is tight 3 Make sure wire nut connections are not rubbing against each other or the interior wall of the switch housing CAUTION Make sure main power is off 4 Allow a 24 h...

Страница 14: ...ot be responsible for how the product is installed or used Before purchase and use of a product please review the product application and national and local codes and regulations and be sure that the...