- 39 -
Set the Auto Load Function
Press the ‘Settings View button’
•
Scroll to 1000 GENERAL SETTINGS
•
Press ‘Enter button’
•
Scroll to 1160 Auto Load
•
Enter the FUNCTION menu
•
Scroll to Auto Load setting
•
Press ‘Enter button’.
Now the Auto Load function is active, and as soon as the
unit is Ready to Start, the display will show the Auto Load
icon
If ‘Function’ is set to ‘Off’, both Auto Load and Auto No-
Load functions are disabled.
If ‘Function’ is set to ‘Auto Load’, then only the Auto
Load function is enabled. In this mode, the machine will
remain loaded regardless of Operation Mode Command
setting.
If ‘Function’ is set to ‘Auto No-Load’, then only the Auto
No-Load function is enabled. In this mode, the loaded
machine will operate loaded for the time configured in
‘Timer’ before reverting back to the No Load state.
If ‘Function’ is set to ‘Auto No-Load + Reload’, then both
automatic loading and unloading functionalities are
enabled, and the machine will start and stop as dictated by
the sensor’s pressure set point and timer setting.
Auto Start/Auto Stop
Parameter 1170 – Auto Start, 1180 – Auto Stop
If ‘Enable’ is set to ‘On’, the machine will attempt to start
if the measured value of the selected sensor goes below the
configured ‘Pressure’ for an elapsed time configured by
‘Delay’.
When ‘Enable’ is set to ‘On’, ‘Function’ (parameter 1160)
is automatically set to ‘Auto Load’.
If you are using an external sensor to control automatic
functionality, the sensor’s pressure values at 0.5V and
4.5V must be specified in 13180 parameter.
If ‘Function’ is set to ‘On’, the machine engine will stop
after being in Loaded Sequence for the elapsed time
configured in ‘Timer’.
Once desired Auto Load, Auto Start, Auto Stop and
external sensor range (if applicable) is defined, finally go
to parameter 1100 and set the operation mode to
AUTOMATIC, as the machine may start prematurely if
this parameter is set earlier.
Once set to AUTOMATIC, the Automatic operation icon
appears.
If the automatic Operation Mode is active, but both Auto
Start and Auto Stop are disabled, a red slash appears of the
Automatic operation icon to indicate the machine will not
perform automatically.
Suggested Atlas Copco transducers
Parameters 1160 – 1180 can be configured
in any order and will remain inactive until
Operation
Mode
Command
(parameter1100)
is
configured
to
‘Automatic’. Parameter 1100 must be
configured last or the machine may start
prematurely if this parameter is set earlier.
Atlas Copco Model No.
Pressure (in bar)
1089957963
0 to 25
1089957964
0 to 50
1089957971
-1 to 5
1089957972
-1 to 17
1089957974
0 to 17
1089957975
0 to 35
1089957976
0 to 50
Содержание XAS 185 KDU T4F HOP
Страница 2: ......
Страница 14: ... 14 Main parts ...
Страница 16: ... 16 Overview COMPRESSOR REGULATING SYSTEM LOAD CONDITION ...
Страница 20: ... 20 Electrical system Circuit Diagram 1310 3200 51 ...
Страница 21: ... 21 ...
Страница 49: ... 49 Adjustments and servicing procedures ADJUSTMENT OF THE CONTINUOUS REGULATING SYSTEM ...
Страница 57: ... 57 Altitude unit performance curve ...
Страница 59: ... 59 Maintenance log Compressor Customer Serial number Service hours Maintenance action Date By initials ...
Страница 60: ... 60 ...
Страница 61: ......
Страница 62: ...www atlascopco com ...